Ghaddar Generators powered by Kubota provide heavy duty and efficient power. The Kubota engines fitted on Ghaddar Generators enjoy excellent features and characteristics. Very well known for their robustness, the result of the Japanese technology with world-class manufacturing standards provides a consistent reliable quality, design diversity for multiple solutions, multiple emission levels and various fuel & Gas options (Diesel, Gasoline, LPG and Natural gas).
Ghaddar Generators powered by Kubota


The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.
NOTES
-
The applicable voltage range is 380V to 415V for 50Hz applications. For other voltages, please consult factory.
-
This generating set is of fixed speed of 1500 rpm.
-
KT9 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
-
KT10S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data |
|
Make & Model |
KUBOTA D1105-E2-BG |
Cylinders & Arrangement |
3; vertical in-line |
Bore & Stroke (mm) |
78 x 78.4 |
Induction system |
Naturally aspirated |
Combustion |
Indirect injection |
Cycle |
4 stroke |
Compression ratio |
24 |
Cooling System |
Water cooled |
Displacement |
1.123 liters |
Lube oil capacity |
5.1 liters Max |
Coolant capacity |
5.1 liters |
Standard governor (Optional) |
Mechanical +/-5% (Electronic) |
Engine Speed |
1500 rpm |
Fuel Consumption @ 100% Load |
2.45 (L/H) |
Fuel Consumption @ 75% Load |
1.84 (L/H) |
Fuel Consumption @ 50% Load |
1.23 (L/H) |
Fuel Consumption @ 25% Load |
0.62 (L/H) |
Radiator Cooling Air Flow (m3/s) |
0.35 |
Emissions regulations |
For non-regulated territories |
Exhaust temperature ᵒC (max) |
500 |
Max exhaust gas flow (m3/min) |
2.24 |
Max. allowed back pressure (kPa) |
7.1 |
The above performance data are valid as per the following specs:
-
Diesel Fuel is according to BS2869 Class A2 or equivalent.
-
Lubricating oil is according to Grade SAE 15W-40 API CI4.
-
The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data |
|
Make & Model |
Leroy Somer TAL040C |
Frequency / No. of poles |
50Hz / 4P |
Ingress protection |
IP23 |
Insulation class |
H |
Terminals (Optional) |
6 (12) |
Excitation system |
SHUNT |
Winding pitch |
2/3 |
AVR model |
R120 |
Overspeed |
2250 R.P.M. |
Voltage regulation |
± 1 % |
Coolant air flow |
0.06 m3/s |
Certification
-
The complete generating set is type-tested according to ISO 8528-8 standard.
Control Panel Specifications
GMP260MK (DSE6110 MKIII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939. It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6120MKIII can be offered.
Circuit Breaker Schneider or ABB, 3 Pole MCB (4 Pole available as Optional)
Construction
Sheet Fabrication |
CNC shearing & bending |
Paint type |
Heat-treated powder-coated |
Paint application |
Electrostatic corona spraying |
Durability tests |
|
Compliance |
|
Degree of protection |
IP55 |
Wire crimping |
|
Wire coding |
|

Genset Standard Features
Assembly:
Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.
Fabrication:
– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.
– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.
– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.
– The control panel enclosure is made up of reliable metal sheet.
Paint:
-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.
– Paints passed durability tests conforming to international quality standards.
– Impact (EN ISO 6272)
– Salt Spray Resistance (ASTM B117-73)
– Humidity Resistance (ASTM D2247)
Works-Testing:
– All Gensets are tested prior to dispatch.
– Test is automatically generated and checked according to ISO8528
– Test certificate is issued for each Genset
Equipment:
– Water cooled Radiator with belt driven blower fan and full guarding
– Electric starter with solenoid Relay
– Battery Charging Alternator
– Energized to run solenoid
– Replaceable fuel, oil and air filters
– Heavy duty leads acid battery with matching capacity (Amps & CCA)
– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.
– Integral Fuel Tank with 67 L capacity.
Documentation:
– User Manual for Operation, Installation and Maintenance guidance
– Wring Diagram.
– Test Report
– Maintenance Schedule
– Catalogues for Engine, Alternator & AVR
Genset Optional Features
Manual & Automatic Transfer Switches,
Synchronizing & Totalizing Panels
Fuel water separator
Water jacket heater
Oil heater
Fuel heater
Battery heater
Anti-condensation Heater
Air Shut-off Valve
Oil Sampler
Pre-lube Oil Pump


- The applicable voltage range is 230V for 50Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1500 rpm.
- KT9 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT10S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA D1105-E2-BG |
Cylinders & Arrangement | 3; vertical in-line |
Bore & Stroke (mm) | 78 x 78.4 |
Induction system | Naturally aspirated |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 24 |
Cooling System | Water cooled |
Displacement | 1.123 liters |
Lube oil capacity | 5.1 liters Max |
Coolant capacity | 5.1 liters |
Standard governor (Optional) | Mechanical +/-5% (Electronic) |
Engine Speed | 1500 rpm |
Fuel Consumption @ 100% Load | 2.45 (L/H) |
Fuel Consumption @ 75% Load | 1.84 (L/H) |
Fuel Consumption @ 50% Load | 1.23 (L/H) |
Fuel Consumption @ 25% Load | 0.62 (L/H) |
Radiator Cooling Air Flow (m3/s) | 0.35 |
Emissions regulations | For non-regulated territories |
Exhaust temperature ᵒC (max) | 500 |
Max exhaust gas flow (m3/min) | 2.24 |
Max. allowed back pressure (kPa) | 7.1 |
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL040C |
Frequency / No. of poles | 50Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Coolant air flow | 0.06 m3/s |
- The complete generating set is type-tested according to ISO 8528-8 standard.

Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]§ Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]§ Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN§ Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section§ Wires are coded by printed numbers § Wires are coded by printed function of the wire |

- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355


- The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1800 rpm.
- KT11 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT12S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA D1105-E2-BG |
Cylinders & Arrangement | 3; vertical in-line |
Bore & Stroke (mm) | 78 x 78.4 |
Induction system | Naturally aspirated |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 24 |
Cooling System | Water cooled |
Displacement | 1.123 liters |
Lube oil capacity | 5.1 liters Max |
Coolant capacity | 5.1 liters |
Standard governor (Optional) | Mechanical +/-5% (Electronic) |
Engine Speed | 1800 rpm |
Fuel Consumption @ 100% Load | 2.6 (L/H) |
Fuel Consumption @ 75% Load | 1.95 (L/H) |
Fuel Consumption @ 50% Load | 1.3 (L/H) |
Fuel Consumption @ 25% Load | 0.65 (L/H) |
Radiator Cooling Air Flow (m3/s) | 0.44 |
Emissions regulations | For non-regulated territories |
Exhaust temperature ᵒC (max) | 500 |
Max exhaust gas flow (m3/min) | 2.64 |
Max. allowed back pressure (kPa) | 7.1 |
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL040C |
Frequency / No. of poles | 60Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Alternator air flow | 0.07 m3/s |
- The complete generating set is type-tested according to ISO 8528-8 standard.

Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272] § Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8] § Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN § Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section § Wires are coded by printed numbers § Wires are coded by printed function of the wire |

- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355
The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.
NOTES
-
The applicable voltage range is 380V to 415V for 50Hz applications. For other voltages, please consult factory.
-
This generating set is of fixed speed of 1500 rpm.
-
KT12 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
-
KT13S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data |
|
Make & Model |
KUBOTA V1505-E2-BG |
Cylinders & Arrangement |
4; vertical in-line |
Bore & Stroke (mm) |
78 x 78.4 |
Induction system |
Naturally aspirated |
Combustion |
Indirect injection |
Cycle |
4 stroke |
Compression ratio |
23:1 |
Cooling System |
Water cooled |
Displacement |
1.498 liters |
Lube oil capacity |
6.0 liters Max |
Coolant capacity |
6.7 liters |
Standard governor (Optional) |
Mechanical +/-5% (Electronic) |
Engine Speed |
1500 rpm |
Fuel Consumption @ 100% Load |
3.23 (L/H) |
Fuel Consumption @ 75% Load |
2.43 (L/H) |
Fuel Consumption @ 50% Load |
1.62 (L/H) |
Fuel Consumption @ 25% Load |
0.81 (L/H) |
Radiator Cooling Air Flow (m3/s) |
0.48 |
Emissions regulations |
For non-regulated territories |
Exhaust temperature ᵒC (max) |
500 |
Max exhaust gas flow (m3/min) |
2.99 |
Max. allowed back pressure (kPa) |
7.1 |
The above performance data are valid as per the following specs:
-
Diesel Fuel is according to BS2869 Class A2 or equivalent.
-
Lubricating oil is according to Grade SAE 15W-40 API CI4.
-
The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data |
|
Make & Model |
Leroy Somer TAL040C |
Frequency / No. of poles |
50 Hz / 4P |
Ingress protection |
IP23 |
Insulation class |
H |
Terminals (Optional) |
6 (12) |
Excitation system |
SHUNT |
Winding pitch |
2/3 |
AVR model |
R120 |
Overspeed |
2250 R.P.M. |
Voltage regulation |
± 1 % |
Coolant air flow |
0.06 m3/s |
Certification
-
The complete generating set is type-tested according to ISO 8528-8 standard.
Control Panel Specifications

GMP260MKIII (DSE6110 MKIII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939. It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6110MKIII can be offered.
Circuit Breaker Schneider or ABB, 3 Pole MCB (4 Pole available as Optional)
Construction
Sheet Fabrication |
CNC shearing & bending |
Paint type |
Heat-treated powder-coated |
Paint application |
Electrostatic corona spraying |
Durability tests |
|
Compliance |
|
Degree of protection |
IP55 |
Wire crimping |
|
Wire coding |
|
Genset Standard Features
Assembly:
Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.
Fabrication:
– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.
– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.
– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.
– The control panel enclosure is made up of reliable metal sheet.
Paint:
-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.
– Paints passed durability tests conforming to international quality standards.
– Impact (EN ISO 6272)
– Salt Spray Resistance (ASTM B117-73)
– Humidity Resistance (ASTM D2247)
Works-Testing:
– All Gensets are tested prior to dispatch.
– Test is automatically generated and checked according to ISO8528
– Test certificate is issued for each Genset
Equipment:
– Water cooled Radiator with belt driven blower fan and full guarding
– Electric starter with solenoid Relay
– Battery Charging Alternator
– Energized to run solenoid
– Replaceable fuel, oil and air filters
– Heavy duty leads acid battery with matching capacity (Amps & CCA)
– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.
– Integral Fuel Tank with 67 L capacity.
Documentation:
– User Manual for Operation, Installation and Maintenance guidance
– Wring Diagram.
– Test Report
– Maintenance Schedule
– Catalogues for Engine, Alternator & AVR
Genset Optional Features
Manual & Automatic Transfer Switches,
Synchronizing & Totalizing Panels
Fuel water separator
Water jacket heater
Oil heater
Fuel heater
Battery heater
Anti-condensation Heater
Air Shut-off Valve
Oil Sampler
Pre-lube Oil Pump


- The applicable voltage range is 230V for 50Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1500 rpm.
- KT12.5 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT13.5S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA V1505-E2-BG |
Cylinders & Arrangement | 4; vertical in-line |
Bore & Stroke (mm) | 78 x 78.4 |
Induction system | Naturally aspirated |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 23 |
Cooling System | Water cooled |
Displacement | 1.498 liters |
Lube oil capacity | 6.0 liters Max |
Coolant capacity | 6.7 liters |
Standard governor (Optional) | Mechanical +/-5% (Electronic) |
Engine Speed | 1500 rpm |
Fuel Consumption @ 100% Load | 3.23 (L/H) |
Fuel Consumption @ 75% Load | 2.43 (L/H) |
Fuel Consumption @ 50% Load | 1.62 (L/H) |
Fuel Consumption @ 25% Load | 0.81 (L/H) |
Radiator Cooling Air Flow (m3/s) | 0.48 |
Emissions regulations | For non-regulated territories |
Exhaust temperature ᵒC (max) | 500 |
Max exhaust gas flow (m3/min) | 2.99 |
Max. allowed back pressure (kPa) | 7.1 |
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL040F |
Frequency / No. of poles | 50Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Coolant air flow | 0.06 m3/s |
- The complete generating set is type-tested according to ISO 8528-8 standard.

Control Panel
Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]§ Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]§ Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN§ Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section§ Wires are coded by printed numbers § Wires are coded by printed function of the wire |

- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355


- The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1800 rpm.
- KT12.5 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT14S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA D1703-E2-BG |
Cylinders & Arrangement | 3; vertical in-line |
Bore & Stroke (mm) | 87 x 92.4 |
Induction system | Naturally aspirated |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 22.6 |
Cooling System | Water cooled |
Displacement | 1.647 liters |
Lube oil capacity | 5.6 liters Max |
Coolant capacity | 5.5 liters |
Standard governor | Isochronous Electronic |
Engine Speed | 1800 rpm |
Fuel Consumption @ 100% Load | 3.9 (L/H) |
Fuel Consumption @ 75% Load | 2.925 (L/H) |
Fuel Consumption @ 50% Load | 1.95 (L/H) |
Fuel Consumption @ 25% Load | 0.975 (L/H) |
Radiator Cooling Air Flow (m3/s) | 0.61 |
Emissions regulations | For non-regulated territories |
Exhaust temperature ᵒC (max) | 500 |
Max exhaust gas flow (m3/min) | 3.87 |
Max. allowed back pressure (kPa) | 7.1 |
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL040C |
Frequency / No. of poles | 60Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Alternator air flow | 0.07 m3/s |
- The complete generating set is type-tested according to ISO 8528-8 standard.

Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272] § Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8] § Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN § Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section § Wires are coded by printed numbers § Wires are coded by printed function of the wire |

- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355


Engine Technical Data |
|
Make & Model |
KUBOTA V1505-E2-BG |
Cylinders & Arrangement |
4; vertical in-line |
Bore & Stroke (mm) |
78 x 78.4 |
Induction system |
Naturally aspirated |
Combustion |
Indirect injection |
Cycle |
4 stroke |
Compression ratio |
23:1 |
Cooling System |
Water cooled |
Displacement |
1.498 liters |
Lube oil capacity |
6.0 liters Max |
Coolant capacity |
6.7 liters |
Standard governor (Optional) |
Mechanical +/-5% (Electronic) |
Engine Speed |
1500 rpm |
Fuel Consumption @ 100% Load |
3.23 (L/H) |
Fuel Consumption @ 75% Load |
2.43 (L/H) |
Fuel Consumption @ 50% Load |
1.62 (L/H) |
Fuel Consumption @ 25% Load |
0.81 (L/H) |
Radiator Cooling Air Flow (m3/s) |
0.48 |
Emissions regulations |
For non-regulated territories |
Exhaust temperature ᵒC (max) |
500 |
Max exhaust gas flow (m3/min) |
2.99 |
Max. allowed back pressure (kPa) |
7.1 |
The above performance data are valid as per the following specs:
-
Diesel Fuel is according to BS2869 Class A2 or equivalent.
-
Lubricating oil is according to Grade SAE 15W-40 API CI4.
-
The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data
Make & Model
Leroy Somer TAL040F
Frequency / No. of poles
50 Hz / 4P
Ingress protection
IP23
Insulation class
H
Terminals (Optional)
6 (12)
Excitation system
SHUNT
Winding pitch
2/3
AVR model
R120
Overspeed
2250 R.P.M.
Voltage regulation
± 1 %
Coolant air flow
0.06 m3/s
Certification
-
The complete generating set is type-tested according to ISO 8528-8 standard.
-
Control Panel Specifications
GMP260MKIII (DSE6110 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939. It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.
Circuit Breaker Schneider or ABB, 3 Pole MCB (4 Pole available as Optional)
-
Construction
-
Sheet Fabrication
CNC shearing & bending
Paint type
Heat-treated powder-coated
Paint application
Electrostatic corona spraying
Durability tests
- IMPACT [EN ISO 6272]
- Salt spray resistance [ASTM B117-73]
- Humidity Resistance [ASTM D2247]
Compliance
-
Panel is compliant with [ISO8528-8]
-
Clearance & Creepage [IEC60355-1]
-
Leakage current & Dielectric strength [IEC60355-1]
-
Protection against electric shock [IEC600 364-4-41]
Degree of protection
IP55
Wire crimping
-
Crimping force up to 20KN
-
Accuracy of 0.01mm
-
Each crimping is checked by Komax CFA+
Wire coding
-
Wires are coded by wire color and cross-section
-
Wires are coded by printed numbers
-
Wires are coded by printed function of the wire
-
Genset Standard Features
Assembly:
Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.
Fabrication:
– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.
– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.
– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.
– The control panel enclosure is made up of reliable metal sheet.
Paint:
-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.
– Paints passed durability tests conforming to international quality standards.
– Impact (EN ISO 6272)
– Salt Spray Resistance (ASTM B117-73)
– Humidity Resistance (ASTM D2247)
Works-Testing:
– All Gensets are tested prior to dispatch.
– Test is automatically generated and checked according to ISO8528
– Test certificate is issued for each Genset
Equipment:
– Water cooled Radiator with belt driven blower fan and full guarding
– Electric starter with solenoid Relay
– Battery Charging Alternator
– Energized to run solenoid
– Replaceable fuel, oil and air filters
– Heavy duty leads acid battery with matching capacity (Amps & CCA)
– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.
– Integral Fuel Tank with 67 L capacity.
Documentation:
– User Manual for Operation, Installation and Maintenance guidance
– Wring Diagram.
– Test Report
– Maintenance Schedule
– Catalogues for Engine, Alternator & AVR
Genset Optional Features
Manual & Automatic Transfer Switches,
Synchronizing & Totalizing Panels
Fuel water separator
Water jacket heater
Oil heater
Fuel heater
Battery heater
Anti-condensation Heater
Air Shut-off Valve
Oil Sampler
Pre-lube Oil Pump
The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.
NOTES
-
The applicable voltage range is 380V to 415V for 50Hz applications. For other voltages, please consult factory.
-
This generating set is of fixed speed of 1500 rpm.
-
KT12.5 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
-
KT14S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data |
|
Make & Model |
KUBOTA D1703-E2-BG |
Cylinders & Arrangement |
3; vertical in-line |
Bore & Stroke (mm) |
87 x 92.4 |
Induction system |
Naturally aspirated |
Combustion |
Indirect injection |
Cycle |
4 stroke |
Compression ratio |
22.6 |
Cooling System |
Water cooled |
Displacement |
1.647 liters |
Lube oil capacity |
5.6 liters Max |
Coolant capacity |
5.5 liters |
Standard governor |
Mechanical +/-5% (Electronic) |
Engine Speed |
1500 rpm |
Fuel Consumption @ 110% Load |
3.7(L/H) |
Fuel Consumption @ 100% Load |
3.4 (L/H) |
Fuel Consumption @ 75% Load |
2.60 (L/H) |
Fuel Consumption @ 50%Load |
1.80(L/H) |
Radiator Cooling Air Flow (m3/s) |
0.49 |
Emissions regulations |
EPA/CARB Tier 2 |
Exhaust temperature ᵒC (max) |
500 |
Max exhaust gas flow (m3/min) |
3.29 |
Max. allowed back pressure (kPa) |
7.1 |
The above performance data are valid as per the following specs:
-
Diesel Fuel is according to BS2869 Class A2 or equivalent.
-
Lubricating oil is according to Grade SAE 15W-40 API CI4.
-
The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data |
|
Make & Model |
Leroy Somer TAL040C |
Frequency / No. of poles |
50Hz / 4P |
Ingress protection |
IP23 |
Insulation class |
H |
Terminals (Optional) |
6 (12) |
Excitation system |
SHUNT |
Winding pitch |
2/3 |
AVR model |
R120 |
Overspeed |
2250 R.P.M. |
Voltage regulation |
± 1 % |
Coolant air flow |
0.06 m3/s |
Control Panel Specifications
GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939. It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.
Circuit Breaker Schneider or ABB, 3 Pole MCB (4 Pole available as Optional)
Construction
Sheet Fabrication |
CNC shearing & bending |
Paint type |
Heat-treated powder-coated |
Paint application |
Electrostatic corona spraying |
Durability tests |
|
Compliance |
|
Degree of protection |
IP55 |
Wire crimping |
|
Wire coding |
|
Genset Standard Features
Assembly:
Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.
Fabrication:
– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.
– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.
– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.
– The control panel enclosure is made up of reliable metal sheet.
Paint:
-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.
– Paints passed durability tests conforming to international quality standards.
– Impact (EN ISO 6272)
– Salt Spray Resistance (ASTM B117-73)
– Humidity Resistance (ASTM D2247)
Works-Testing:
– All Gensets are tested prior to dispatch.
– Test is automatically generated and checked according to ISO8528
– Test certificate is issued for each Genset
Equipment:
– Water cooled Radiator with belt driven blower fan and full guarding
– Electric starter with solenoid Relay
– Battery Charging Alternator
– Energized to run solenoid
– Replaceable fuel, oil and air filters
– Heavy duty leads acid battery with matching capacity (Amps & CCA)
– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.
– Integral Fuel Tank with 67 L capacity.
Documentation:
– User Manual for Operation, Installation and Maintenance guidance
– Wring Diagram.
– Test Report
– Maintenance Schedule
– Catalogues for Engine, Alternator & AVR
Genset Optional Features
Manual & Automatic Transfer Switches,
Synchronizing & Totalizing Panels
Fuel water separator
Water jacket heater
Oil heater
Fuel heater
Battery heater
Anti-condensation Heater
Air Shut-off Valve
Oil Sampler
Pre-lube Oil Pump


- The applicable voltage range is 230V for 50Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1500 rpm.
- KT14 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT16S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA D1703-E2-BG-GDR1 |
Cylinders & Arrangement | 3; vertical in-line |
Bore & Stroke (mm) | 87 x 92.4 |
Induction system | Naturally aspirated |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 22.6 |
Cooling System | Water cooled |
Displacement | 1.647 liters |
Lube oil capacity | 5.6 liters Max |
Coolant capacity | 5.5 liters |
Standard governor | Isochronous Electronic |
Engine Speed | 1500 rpm |
Fuel Consumption @ 100% Load | 3.51 (L/H) |
Fuel Consumption @ 75% Load | 2.64 (L/H) |
Fuel Consumption @ 50% Load | 1.76 (L/H) |
Fuel Consumption @ 25% Load | 0.88 (L/H) |
Radiator Cooling Air Flow (m3/s) | 0.49 |
Emissions regulations | For non-regulated territories |
Exhaust temperature ᵒC (max) | 500 |
Max exhaust gas flow (m3/min) | 3.29 |
Max. allowed back pressure (kPa) | 7.1 |
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL040F |
Frequency / No. of poles | 50Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Coolant air flow | 0.06 m3/s |
- The complete generating set is type-tested according to ISO 8528-8 standard.

Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]§ Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]§ Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN§ Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section§ Wires are coded by printed numbers § Wires are coded by printed function of the wire |

- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355


- The applicable voltage range is 230V for 50Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1500 rpm.
- KT14 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT16S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA V2203-E2-BG |
Cylinders & Arrangement | 4; vertical in-line |
Bore & Stroke (mm) | 87 x 92.4 |
Induction system | Naturally aspirated |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 22 |
Cooling System | Water cooled |
Displacement | 2.197 liters |
Lube oil capacity | 7.6 liters Max |
Coolant capacity | 8.1 liters |
Standard governor | Isochronous Electronic |
Engine Speed | 1500 rpm |
Fuel Consumption @ 100% Load | 4.72 (L/H) |
Fuel Consumption @ 75% Load | 3.54 (L/H) |
Fuel Consumption @ 50% Load | 2.36 (L/H) |
Fuel Consumption @ 25% Load | 1.18 (L/H) |
Radiator Cooling Air Flow (m3/s) | 0.64 |
Emissions regulations | EU Stage IIIA |
Exhaust temperature ᵒC (max) | 500 |
Max exhaust gas flow (m3/min) | 4.39 |
Max. allowed back pressure (kPa) | 7.1 |
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL040F |
Frequency / No. of poles | 50Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Coolant air flow | 0.06 m3/s |
- The complete generating set is type-tested according to ISO 8528-8 standard.

Control Panel
Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]§ Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]§ Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN§ Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section§ Wires are coded by printed numbers § Wires are coded by printed function of the wire |

- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355


- The applicable voltage range is 230V for 50Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1500 rpm.
- KT15 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT17S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA V2203-E2-BG-GDR1 |
Cylinders & Arrangement | 4; vertical in-line |
Bore & Stroke (mm) | 87 x 92.4 |
Induction system | Naturally aspirated |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 22 |
Cooling System | Water cooled |
Displacement | 2.197 liters |
Lube oil capacity | 7.6 liters Max |
Coolant capacity | 8.1 liters |
Standard governor | Isochronous Electronic |
Engine Speed | 1500 rpm |
Fuel Consumption @ 100% Load | 4.72 (L/H) |
Fuel Consumption @ 75% Load | 3.54 (L/H) |
Fuel Consumption @ 50% Load | 2.36 (L/H) |
Fuel Consumption @ 25% Load | 1.18 (L/H) |
Radiator Cooling Air Flow (m3/s) | 0.64 |
Emissions regulations | EU Stage IIIA |
Exhaust temperature ᵒC (max) | 500 |
Max exhaust gas flow (m3/min) | 4.39 |
Max. allowed back pressure (kPa) | 7.1 |
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL042A |
Frequency / No. of poles | 50Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Coolant air flow | 0.1 m3/s |
- The complete generating set is type-tested according to ISO 8528-8 standard.

Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]§ Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]§ Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN§ Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section§ Wires are coded by printed numbers § Wires are coded by printed function of the wire |

- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355

The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.
NOTES
-
The applicable voltage range is 380V to 415V for 50Hz applications. For other voltages, please consult factory.
-
This generating set is of fixed speed of 1500 rpm.
-
KT15 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
-
KT16S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data |
|
Make & Model |
KUBOTA D1703-E2-BG-GDR1 |
Cylinders & Arrangement |
3; vertical in-line |
Bore & Stroke (mm) |
87 x 92.4 |
Induction system |
Naturally aspirated |
Combustion |
Indirect injection |
Cycle |
4 stroke |
Compression ratio |
22.6 |
Cooling System |
Water cooled |
Displacement |
1.647 liters |
Lube oil capacity |
5.6 liters Max |
Coolant capacity |
5.5 liters |
Standard governor |
Mechanical +/-5% (Electronic) |
Engine Speed |
1500 rpm |
Fuel Consumption @ 100% Load |
3.51 (L/H) |
Fuel Consumption @ 75% Load |
2.64 (L/H) |
Fuel Consumption @ 50% Load |
1.76 (L/H) |
Fuel Consumption @ 25% Load |
0.88 (L/H) |
Radiator Cooling Air Flow (m3/s) |
0.49 |
Emissions regulations |
EPA/CARB Tier 2 |
Exhaust temperature ᵒC (max) |
500 |
Max exhaust gas flow (m3/min) |
3.29 |
Max. allowed back pressure (kPa) |
7.1 |
The above performance data are valid as per the following specs:
-
Diesel Fuel is according to BS2869 Class A2 or equivalent.
-
Lubricating oil is according to Grade SAE 15W-40 API CI4.
-
The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data |
|
Make & Model |
Leroy Somer TAL040F |
Frequency / No. of poles |
50Hz / 4P |
Ingress protection |
IP23 |
Insulation class |
H |
Terminals (Optional) |
6 (12) |
Excitation system |
SHUNT |
Winding pitch |
2/3 |
AVR model |
R120 |
Overspeed |
2250 R.P.M. |
Voltage regulation |
± 1 % |
Coolant air flow |
0.06 m3/s |
Certification
-
The complete generating set is type-tested according to ISO 8528-8 standard.
Control Panel Specifications
GMP260MK (DSE6110 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939. It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6120MKII can be offered.
Circuit Breaker Schneider or ABB, 3 Pole MCB (4 Pole available as Optional)
Construction
Sheet Fabrication |
CNC shearing & bending |
Paint type |
Heat-treated powder-coated |
Paint application |
Electrostatic corona spraying |
Durability tests |
|
Compliance |
|
Degree of protection |
IP55 |
Wire crimping |
|
Wire coding |
|

Genset Standard Features
Assembly:
Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.
Fabrication:
– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.
– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.
– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.
– The control panel enclosure is made up of reliable metal sheet.
Paint:
-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.
– Paints passed durability tests conforming to international quality standards.
– Impact (EN ISO 6272)
– Salt Spray Resistance (ASTM B117-73)
– Humidity Resistance (ASTM D2247)
Works-Testing:
– All Gensets are tested prior to dispatch.
– Test is automatically generated and checked according to ISO8528
– Test certificate is issued for each Genset
Equipment:
– Water cooled Radiator with belt driven blower fan and full guarding
– Electric starter with solenoid Relay
– Battery Charging Alternator
– Energized to run solenoid
– Replaceable fuel, oil and air filters
– Heavy duty leads acid battery with matching capacity (Amps & CCA)
– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.
– Integral Fuel Tank with 67 L capacity.
Documentation:
– User Manual for Operation, Installation and Maintenance guidance
– Wring Diagram.
– Test Report
– Maintenance Schedule
– Catalogues for Engine, Alternator & AVR
Genset Optional Features
Manual & Automatic Transfer Switches,
Synchronizing & Totalizing Panels
Fuel water separator
Water jacket heater
Oil heater
Fuel heater
Battery heater
Anti-condensation Heater
Air Shut-off Valve
Oil Sampler
Pre-lube Oil Pump


- The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1800 rpm.
- KT15 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT17S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA V1505-E2-BG |
Cylinders & Arrangement | 4; vertical in-line |
Bore & Stroke (mm) | 78 x 78.4 |
Induction system | Naturally aspirated |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 23:1 |
Cooling System | Water cooled |
Displacement | 1.498 liters |
Lube oil capacity | 6.0 liters Max |
Coolant capacity | 6.7 liters |
Standard governor (Optional) | Mechanical +/-5% (Electronic) |
Engine Speed | 1800 rpm |
Fuel Consumption @ 100% Load | 3.5 (L/H) |
Fuel Consumption @ 75% Load | 2.63 (L/H) |
Fuel Consumption @ 50% Load | 1.75 (L/H) |
Fuel Consumption @ 25% Load | 0.875 (L/H) |
Radiator Cooling Air Flow (m3/s) | 0.48 |
Emissions regulations | EPA/CARB TIER 2 |
Exhaust temperature ᵒC (max) | 500 |
Max exhaust gas flow (m3/min) | 3.52 |
Max. allowed back pressure (kPa) | 7.1 |
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL040F |
Frequency / No. of poles | 60HZ / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Alternator air flow | 0.07 m3/s |
- The complete generating set is type-tested according to ISO 8528-8 standard.

Control Panel
Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]§ Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]§ Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN§ Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section§ Wires are coded by printed numbers § Wires are coded by printed function of the wire |

- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355


- The applicable voltage range is 230V for 50Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1500 rpm.
- KT17 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT19S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA V2203-E2-BG |
Cylinders & Arrangement | 4; vertical in-line |
Bore & Stroke (mm) | 87 x 92.4 |
Induction system | Naturally aspirated |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 22 |
Cooling System | Water cooled |
Displacement | 2.197 liters |
Lube oil capacity | 7.6 liters Max |
Coolant capacity | 8.1 liters |
Standard governor | Isochronous Electronic |
Engine Speed | 1500 rpm |
Fuel Consumption @ 100% Load | 4.72 (L/H) |
Fuel Consumption @ 75% Load | 3.54 (L/H) |
Fuel Consumption @ 50% Load | 2.36 (L/H) |
Fuel Consumption @ 25% Load | 1.18 (L/H) |
Radiator Cooling Air Flow (m3/s) | 0.64 |
Emissions regulations | EU Stage IIIA |
Exhaust temperature ᵒC (max) | 500 |
Max exhaust gas flow (m3/min) | 4.39 |
Max. allowed back pressure (kPa) | 7.1 |
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL042B (M) |
Frequency / No. of poles | 50Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Coolant air flow | 0.1 m3/s |
- The complete generating set is type-tested according to ISO 8528-8 standard.

Control Panel
Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]§ Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]§ Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN§ Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section§ Wires are coded by printed numbers § Wires are coded by printed function of the wire |

- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355


- The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1800 rpm.
- KT18 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT20S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA D1703-E2-BG-GDR1 |
Cylinders & Arrangement | 3; vertical in-line |
Bore & Stroke (mm) | 87 x 92.4 |
Induction system | Naturally aspirated |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 22.6 |
Cooling System | Water cooled |
Displacement | 1.647 liters |
Lube oil capacity | 5.6 liters Max |
Coolant capacity | 5.5 liters |
Standard governor | Isochronous Electronic |
Engine Speed | 1800 rpm |
Fuel Consumption @ 100% Load | 3.9 (L/H) |
Fuel Consumption @ 75% Load | 2.925 (L/H) |
Fuel Consumption @ 50% Load | 1.95 (L/H) |
Fuel Consumption @ 25% Load | 0.975 (L/H) |
Radiator Cooling Air Flow (m3/s) | 0.61 |
Emissions regulations | For non-regulated territories |
Exhaust temperature ᵒC (max) | 500 |
Max exhaust gas flow (m3/min) | 3.87 |
Max. allowed back pressure (kPa) | 7.1 |
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL040F |
Frequency / No. of poles | 60Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Alternator air flow | 0.07 m3/s |
- The complete generating set is type-tested according to ISO 8528-8 standard.

Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]§ Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]§ Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN§ Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section§ Wires are coded by printed numbers § Wires are coded by printed function of the wire |

- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355


- The applicable voltage range is 230V for 50Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1500 rpm.
- KT19 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT21S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA V2003-T-E2-BG |
Cylinders & Arrangement | 4; vertical in-line |
Bore & Stroke (mm) | 83 x 92.4 |
Induction system | Turbocharged |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 21.7 |
Cooling System | Water cooled |
Displacement | 1.999 liters |
Lube oil capacity | 7.6 liters Max |
Coolant capacity | 8.4 liters |
Standard governor | Isochronous Electronic |
Engine Speed | 1500 rpm |
Fuel Consumption @ 100% Load | 5.6 (L/H) |
Fuel Consumption @ 75% Load | 4.2 (L/H) |
Fuel Consumption @ 50% Load | 2.8 (L/H) |
Fuel Consumption @ 25% Load | 1.4 (L/H) |
Radiator Cooling Air Flow (m3/s) | 0.78 |
Emissions regulations | EU Stage IIIA |
Exhaust temperature ᵒC (max) | 510 |
Max exhaust gas flow (m3/min) | 5.5 |
Max. allowed back pressure (kPa) | 7.1 |
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL042B (M) |
Frequency / No. of poles | 50Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Coolant air flow | 0.1 m3/s |
- The complete generating set is type-tested according to ISO 8528-8 standard.

Control Panel
Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]§ Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]§ Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN§ Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section§ Wires are coded by printed numbers § Wires are coded by printed function of the wire |

- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355
The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.
NOTES
- The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1800 rpm.
- KT20 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT22S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA V2003-T-E2-BG |
Cylinders & Arrangement | 4; vertical in-line |
Bore & Stroke (mm) | 83 x 92.4 |
Induction system | Turbocharged |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 21.7 |
Cooling System | Water cooled |
Displacement | 1.999 liters |
Lube oil capacity | 7.6 liters Max |
Coolant capacity | 8.4 liters |
Standard governor | Isochronous Electronic |
Engine Speed | 1800 rpm |
Fuel Consumption @ 100% Load | 6.2 (L/H) |
Fuel Consumption @ 75% Load | 4.65 (L/H) |
Fuel Consumption @ 50% Load | 3.1 (L/H) |
Fuel Consumption @ 25% Load | 1.55 (L/H) |
Radiator Cooling Air Flow (m3/s) | 0.97 |
Emissions regulations | EU Stage IIIA |
Exhaust temperature ᵒC (max) | 510 |
Max exhaust gas flow (m3/min) | 6.47 |
Max. allowed back pressure (kPa) | 7.1 |
The above performance data are valid as per the following specs:
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL040F |
Frequency / No. of poles | 60Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Alternator air flow | 0.07 m3/s |
Certification
- The complete generating set is type-tested according to ISO 8528-8 standard.
Control Panel Specifications
GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939. It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.
Circuit Breaker Schneider or ABB, 3 Pole MCB (4 Pole available as Optional)
Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]
§ Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]
§ Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN
§ Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section
§ Wires are coded by printed numbers § Wires are coded by printed function of the wire |
Certification
- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355
Genset Standard Features
Assembly:
Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.
Fabrication:
– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.
– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.
– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.
– The control panel enclosure is made up of reliable metal sheet.
Paint:
-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.
– Paints passed durability tests conforming to international quality standards.
– Impact (EN ISO 6272)
– Salt Spray Resistance (ASTM B117-73)
– Humidity Resistance (ASTM D2247)
Works-Testing:
– All Gensets are tested prior to dispatch.
– Test is automatically generated and checked according to ISO8528
– Test certificate is issued for each Genset
Equipment:
– Water cooled Radiator with belt driven blower fan and full guarding
– Electric starter with solenoid Relay
– Battery Charging Alternator
– Energized to run solenoid
– Replaceable fuel, oil and air filters
– Heavy duty leads acid battery with matching capacity (Amps & CCA)
– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.
– Integral Fuel Tank with 67 L capacity.
Documentation:
– User Manual for Operation, Installation and Maintenance guidance
– Wring Diagram.
– Test Report
– Maintenance Schedule
– Catalogues for Engine, Alternator & AVR
Genset Optional Features
Manual & Automatic Transfer Switches,
Synchronizing & Totalizing Panels
Fuel water separator
Water jacket heater
Oil heater
Fuel heater
Battery heater
Anti-condensation Heater
Air Shut-off Valve
Oil Sampler
Pre-lube Oil Pump


- The applicable voltage range is 380V to 415V for 50Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1500 rpm.
- KT20 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT22S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA V2203-E2-BG-GDR1 |
Cylinders & Arrangement | 4; vertical in-line |
Bore & Stroke (mm) | 87 x 92.4 |
Induction system | Naturally aspirated |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 22 |
Cooling System | Water cooled |
Displacement | 2.197 liters |
Lube oil capacity | 9.2 liters Max |
Coolant capacity | 8.1 liters |
Standard governor | Mechanical +/-5% (Electronic) |
Engine Speed | 1500 rpm |
Fuel Consumption @ 100% Load | 4.72 (L/H) |
Fuel Consumption @ 75% Load | 3.54 (L/H) |
Fuel Consumption @ 50% Load | 2.36 (L/H) |
Fuel Consumption @ 25% Load | 1.18 (L/H) |
Radiator Cooling Air Flow (m3/s) | 0.64 |
Emissions regulations | EPA/CARB Tier 2 |
Exhaust temperature ᵒC (max) | 500 |
Max exhaust gas flow (m3/min) | 4.39 |
Max. allowed back pressure (kPa) | 7.1 |
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL040F |
Frequency / No. of poles | 50Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Coolant air flow | 0.06 m3/s |
- The complete generating set is type-tested according to ISO 8528-8 standard.

Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]§ Salt spray resistance [ASTM B117-73]§ Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]§ Clearance & Creepage [IEC60355-1]§ Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN§ Accuracy of 0.01mm§ Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section§ Wires are coded by printed numbers§ Wires are coded by printed function of the wire |

- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355


- The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1800 rpm.
- KT20 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT22S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA V2203-E2-BG-GDR1 |
Cylinders & Arrangement | 4; vertical in-line |
Bore & Stroke (mm) | 87 x 92.4 |
Induction system | Naturally aspirated |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 22 |
Cooling System | Water cooled |
Displacement | 2.197 liters |
Lube oil capacity | 7.6 liters Max |
Coolant capacity | 8.1 liters |
Standard governor | Isochronous Electronic |
Engine Speed | 1800 rpm |
Fuel Consumption @ 100% Load | 5.2 (L/H) |
Fuel Consumption @ 75% Load | 3.9 (L/H) |
Fuel Consumption @ 50% Load | 2.6 (L/H) |
Fuel Consumption @ 25% Load | 1.3 (L/H) |
Radiator Cooling Air Flow (m3/s) | 0.80 |
Emissions regulations | EU Stage IIIA |
Exhaust temperature ᵒC (max) | 500 |
Max exhaust gas flow (m3/min) | 5.17 |
Max. allowed back pressure (kPa) | 7.1 |
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL040F |
Frequency / No. of poles | 60Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Alternator air flow | 0.07 m3/s |
- The complete generating set is type-tested according to ISO 8528-8 standard.

Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]§ Salt spray resistance [ASTM B117-73]§ Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]§ Clearance & Creepage [IEC60355-1]§ Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN§ Accuracy of 0.01mm§ Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section§ Wires are coded by printed numbers§ Wires are coded by printed function of the wire |

- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355
The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.
NOTES
- The applicable voltage range is 380V to 415V for 50Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1500 rpm.
- KT20 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT22S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA V2003-T-E2-BG |
Cylinders & Arrangement | 4; vertical in-line |
Bore & Stroke (mm) | 83 x 92.4 |
Induction system | Turbocharged |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 21.7 |
Cooling System | Water cooled |
Displacement | 1.999 liters |
Lube oil capacity | 7.6 liters Max |
Coolant capacity | 8.4 liters |
Standard governor | Isochronous Electronic |
Engine Speed | 1500 rpm |
Fuel Consumption @ 100% Load | 5.6 (L/H) |
Fuel Consumption @ 75% Load | 4.2 (L/H) |
Fuel Consumption @ 50% Load | 2.8 (L/H) |
Fuel Consumption @ 25% Load | 1.4 (L/H) |
Radiator Cooling Air Flow (m3/s) | 0.78 |
Emissions regulations | EU Stage IIIA |
Exhaust temperature ᵒC (max) | 510 |
Max exhaust gas flow (m3/min) | 5.5 |
Max. allowed back pressure (kPa) | 7.1 |
The above performance data are valid as per the following specs:
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL040F |
Frequency / No. of poles | 50Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Coolant air flow | 0.06 m3/s |
Certification
- The complete generating set is type-tested according to ISO 8528-8 standard.
Control Panel Specifications
GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939. It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.
Circuit Breaker Schneider or ABB, 3 Pole MCB (4 Pole available as Optional)
Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]
§ Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]
§ Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN
§ Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section
§ Wires are coded by printed numbers § Wires are coded by printed function of the wire |
Certification
- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355
Genset Standard Features
Assembly:
Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.
Fabrication:
– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.
– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.
– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.
– The control panel enclosure is made up of reliable metal sheet.
Paint:
-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.
– Paints passed durability tests conforming to international quality standards.
– Impact (EN ISO 6272)
– Salt Spray Resistance (ASTM B117-73)
– Humidity Resistance (ASTM D2247)
Works-Testing:
– All Gensets are tested prior to dispatch.
– Test is automatically generated and checked according to ISO8528
– Test certificate is issued for each Genset
Equipment:
– Water cooled Radiator with belt driven blower fan and full guarding
– Electric starter with solenoid Relay
– Battery Charging Alternator
– Energized to run solenoid
– Replaceable fuel, oil and air filters
– Heavy duty leads acid battery with matching capacity (Amps & CCA)
– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.
– Integral Fuel Tank with 67 L capacity.
Documentation:
– User Manual for Operation, Installation and Maintenance guidance
– Wring Diagram.
– Test Report
– Maintenance Schedule
– Catalogues for Engine, Alternator & AVR
Genset Optional Features
Manual & Automatic Transfer Switches,
Synchronizing & Totalizing Panels
Fuel water separator
Water jacket heater
Oil heater
Fuel heater
Battery heater
Anti-condensation Heater
Air Shut-off Valve
Oil Sampler
Pre-lube Oil Pump


- The applicable voltage range is 380V to 415V for 50Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1500 rpm.
- KT20 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT23S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA V3300-E2-BG2-GDR1 |
Cylinders & Arrangement | 4; vertical in-line |
Bore & Stroke (mm) | 98 x 110 |
Induction system | Naturally aspirated |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 22.6 |
Cooling System | Water cooled |
Displacement | 3.318 liters |
Lube oil capacity | 13.2 liters Max |
Coolant capacity | 13.2 liters |
Standard governor (Optional) | Mechanical +/-5% (Electronic) |
Engine Speed | 1500 rpm |
Fuel Consumption @ 100% Load | 7.15 (L/H) |
Fuel Consumption @ 75% Load | 5.37 (L/H) |
Fuel Consumption @ 50% Load | 3.58 (L/H) |
Fuel Consumption @ 25% Load | 1.79 (L/H) |
Radiator Cooling Air Flow (m3/s) | 0.98 |
Emissions regulations | EU Stage IIIA |
Exhaust temperature ᵒC (max) | 500 |
Max exhaust gas flow (m3/min) | 6.63 |
Max. allowed back pressure (kPa) | 7.1 |
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL042B (M) |
Frequency / No. of poles | 50Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Coolant air flow | 0.1 m3/s |
- The complete generating set is type-tested according to ISO 8528-8 standard.

Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]§ Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]§ Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN§ Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section§ Wires are coded by printed numbers § Wires are coded by printed function of the wire |

- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355
The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.
NOTES
- The applicable voltage range is 380V to 415V for 50Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1500 rpm.
- 5 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT25S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA V2003-T-E2-BG |
Cylinders & Arrangement | 4; vertical in-line |
Bore & Stroke (mm) | 83 x 92.4 |
Induction system | Turbocharged |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 21.7 |
Cooling System | Water cooled |
Displacement | 1.999 liters |
Lube oil capacity | 7.6 liters Max |
Coolant capacity | 8.4 liters |
Standard governor | Isochronous Electronic |
Engine Speed | 1500 rpm |
Fuel Consumption @ 100% Load | 5.6 (L/H) |
Fuel Consumption @ 75% Load | 4.2 (L/H) |
Fuel Consumption @ 50% Load | 2.8 (L/H) |
Fuel Consumption @ 25% Load | 1.4 (L/H) |
Radiator Cooling Air Flow (m3/s) | 0.78 |
Emissions regulations | EU Stage IIIA |
Exhaust temperature ᵒC (max) | 510 |
Max exhaust gas flow (m3/min) | 5.5 |
Max. allowed back pressure (kPa) | 7.1 |
The above performance data are valid as per the following specs:
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL042A |
Frequency / No. of poles | 50Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Coolant air flow | 0.1 m3/s |
Certification
- The complete generating set is type-tested according to ISO 8528-8 standard.
Control Panel Specifications
GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939. It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.
Circuit Breaker Schneider or ABB, 3 Pole MCB (4 Pole available as Optional)
Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]
§ Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]
§ Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN
§ Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section
§ Wires are coded by printed numbers § Wires are coded by printed function of the wire |
Certification
- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355
Genset Standard Features
Assembly:
Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.
Fabrication:
– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.
– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.
– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.
– The control panel enclosure is made up of reliable metal sheet.
Paint:
-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.
– Paints passed durability tests conforming to international quality standards.
– Impact (EN ISO 6272)
– Salt Spray Resistance (ASTM B117-73)
– Humidity Resistance (ASTM D2247)
Works-Testing:
– All Gensets are tested prior to dispatch.
– Test is automatically generated and checked according to ISO8528
– Test certificate is issued for each Genset
Equipment:
– Water cooled Radiator with belt driven blower fan and full guarding
– Electric starter with solenoid Relay
– Battery Charging Alternator
– Energized to run solenoid
– Replaceable fuel, oil and air filters
– Heavy duty leads acid battery with matching capacity (Amps & CCA)
– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.
– Integral Fuel Tank with 67 L capacity.
Documentation:
– User Manual for Operation, Installation and Maintenance guidance
– Wring Diagram.
– Test Report
– Maintenance Schedule
– Catalogues for Engine, Alternator & AVR
Genset Optional Features
Manual & Automatic Transfer Switches,
Synchronizing & Totalizing Panels
Fuel water separator
Water jacket heater
Oil heater
Fuel heater
Battery heater
Anti-condensation Heater
Air Shut-off Valve
Oil Sampler
Pre-lube Oil Pump


- The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1800 rpm.
- KT24 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT27S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA V2203-E2-BG-GDR1 |
Cylinders & Arrangement | 4; vertical in-line |
Bore & Stroke (mm) | 87 x 92.4 |
Induction system | Naturally aspirated |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 22 |
Cooling System | Water cooled |
Displacement | 2.197 liters |
Lube oil capacity | 7.6 liters Max |
Coolant capacity | 8.1 liters |
Standard governor | Isochronous Electronic |
Engine Speed | 1800 rpm |
Fuel Consumption @ 100% Load | 5.2 (L/H) |
Fuel Consumption @ 75% Load | 3.9 (L/H) |
Fuel Consumption @ 50% Load | 2.6 (L/H) |
Fuel Consumption @ 25% Load | 1.3 (L/H) |
Radiator Cooling Air Flow (m3/s) | 0.80 |
Emissions regulations | EU Stage IIIA |
Exhaust temperature ᵒC (max) | 500 |
Max exhaust gas flow (m3/min) | 5.17 |
Max. allowed back pressure (kPa) | 7.1 |
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL042A |
Frequency / No. of poles | 60Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Alternator air flow | 0.07 m3/s |
- The complete generating set is type-tested according to ISO 8528-8 standard.

Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]§ Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]§ Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN§ Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section§ Wires are coded by printed numbers § Wires are coded by printed function of the wire |

- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355


- The applicable voltage range is 230V for 50Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1500 rpm.
- KT27 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT30S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA V3300-E2-BG2-GDR1 |
Cylinders & Arrangement | 4; vertical in-line |
Bore & Stroke (mm) | 98 x 110 |
Induction system | Naturally aspirated |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 22.6 |
Cooling System | Water cooled |
Displacement | 3.318 liters |
Lube oil capacity | 13.2 liters Max |
Coolant capacity | 13.2 liters |
Standard governor (Optional) | Mechanical +/-5% (Electronic) |
Engine Speed | 1500 rpm |
Fuel Consumption @ 100% Load | 7.15 (L/H) |
Fuel Consumption @ 75% Load | 5.37 (L/H) |
Fuel Consumption @ 50% Load | 3.58 (L/H) |
Fuel Consumption @ 25% Load | 1.79 (L/H) |
Radiator Cooling Air Flow (m3/s) | 0.98 |
Emissions regulations | EU Stage IIIA |
Exhaust temperature ᵒC (max) | 500 |
Max exhaust gas flow (m3/min) | 6.63 |
Max. allowed back pressure (kPa) | 7.1 |
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL042F |
Frequency / No. of poles | 50Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Coolant air flow | 0.1 m3/s |
- The complete generating set is type-tested according to ISO 8528-8 standard.

Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]§ Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]§ Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN§ Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section§ Wires are coded by printed numbers § Wires are coded by printed function of the wire |

- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355
The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.
NOTES
- The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1800 rpm.
- KT27 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT30S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA V2003-T-E2-BG |
Cylinders & Arrangement | 4; vertical in-line |
Bore & Stroke (mm) | 83 x 92.4 |
Induction system | Turbocharged |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 21.7 |
Cooling System | Water cooled |
Displacement | 1.999 liters |
Lube oil capacity | 7.6 liters Max |
Coolant capacity | 8.4 liters |
Standard governor | Isochronous Electronic |
Engine Speed | 1800 rpm |
Fuel Consumption @ 100% Load | 6.2 (L/H) |
Fuel Consumption @ 75% Load | 4.65 (L/H) |
Fuel Consumption @ 50% Load | 3.1 (L/H) |
Fuel Consumption @ 25% Load | 1.55 (L/H) |
Radiator Cooling Air Flow (m3/s) | 0.97 |
Emissions regulations | EU Stage IIIA |
Exhaust temperature ᵒC (max) | 510 |
Max exhaust gas flow (m3/min) | 6.47 |
Max. allowed back pressure (kPa) | 7.1 |
The above performance data are valid as per the following specs:
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL042A |
Frequency / No. of poles | 60Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Alternator air flow | 0.07 m3/s |
Certification
- The complete generating set is type-tested according to ISO 8528-8 standard.
Control Panel Specifications
GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939. It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.
Circuit Breaker Schneider or ABB, 3 Pole MCB (4 Pole available as Optional)
Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]
§ Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]
§ Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN
§ Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section
§ Wires are coded by printed numbers § Wires are coded by printed function of the wire |
Certification
- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355
Genset Standard Features
Assembly:
Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.
Fabrication:
– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.
– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.
– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.
– The control panel enclosure is made up of reliable metal sheet.
Paint:
-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.
– Paints passed durability tests conforming to international quality standards.
– Impact (EN ISO 6272)
– Salt Spray Resistance (ASTM B117-73)
– Humidity Resistance (ASTM D2247)
Works-Testing:
– All Gensets are tested prior to dispatch.
– Test is automatically generated and checked according to ISO8528
– Test certificate is issued for each Genset
Equipment:
– Water cooled Radiator with belt driven blower fan and full guarding
– Electric starter with solenoid Relay
– Battery Charging Alternator
– Energized to run solenoid
– Replaceable fuel, oil and air filters
– Heavy duty leads acid battery with matching capacity (Amps & CCA)
– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.
– Integral Fuel Tank with 67 L capacity.
Documentation:
– User Manual for Operation, Installation and Maintenance guidance
– Wring Diagram.
– Test Report
– Maintenance Schedule
– Catalogues for Engine, Alternator & AVR
Genset Optional Features
Manual & Automatic Transfer Switches,
Synchronizing & Totalizing Panels
Fuel water separator
Water jacket heater
Oil heater
Fuel heater
Battery heater
Anti-condensation Heater
Air Shut-off Valve
Oil Sampler
Pre-lube Oil Pump
The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.
NOTES
- The applicable voltage range is 230V for 50Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1500 rpm.
- KT27 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT30S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA V3300-T-E2-BG2 |
Cylinders & Arrangement | 4; vertical in-line |
Bore & Stroke (mm) | 100 x 120 |
Induction system | Turbocharged |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 21.8 |
Cooling System | Water cooled |
Displacement | 3.769 liters |
Lube oil capacity | 13.2 liters Max |
Coolant capacity | 13.2 liters |
Standard governor | Isochronous Electronic |
Engine Speed | 1500 rpm |
Fuel Consumption @ 100% Load | 8.61 (L/H) |
Fuel Consumption @ 75% Load | 6.46 (L/H) |
Fuel Consumption @ 50% Load | 4.31 (L/H) |
Fuel Consumption @ 25% Load | 2.16 (L/H) |
Radiator Cooling Air Flow (m3/s) | 1.19 |
Emissions regulations | EU Stage IIIA |
Exhaust temperature ᵒC (max) | 500 |
Max exhaust gas flow (m3/min) | 9.99 |
Max. allowed back pressure (kPa) | 7.1 |
The above performance data are valid as per the following specs:
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL042F |
Frequency / No. of poles | 50Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Coolant air flow | 0.1 m3/s |
Certification
- The complete generating set is type-tested according to ISO 8528-8 standard.
Control Panel Specifications
GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939. It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.
Circuit Breaker Schneider or ABB, 3 Pole MCB (4 Pole available as Optional)
Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]
§ Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]
§ Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN
§ Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section
§ Wires are coded by printed numbers § Wires are coded by printed function of the wire |
Certification
- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355
Genset Standard Features
Assembly:
Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.
Fabrication:
– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.
– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.
– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.
– The control panel enclosure is made up of reliable metal sheet.
Paint:
-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.
– Paints passed durability tests conforming to international quality standards.
– Impact (EN ISO 6272)
– Salt Spray Resistance (ASTM B117-73)
– Humidity Resistance (ASTM D2247)
Works-Testing:
– All Gensets are tested prior to dispatch.
– Test is automatically generated and checked according to ISO8528
– Test certificate is issued for each Genset
Equipment:
– Water cooled Radiator with belt driven blower fan and full guarding
– Electric starter with solenoid Relay
– Battery Charging Alternator
– Energized to run solenoid
– Replaceable fuel, oil and air filters
– Heavy duty leads acid battery with matching capacity (Amps & CCA)
– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.
– Integral Fuel Tank with 116 L capacity.
Documentation:
– User Manual for Operation, Installation and Maintenance guidance
– Wring Diagram.
– Test Report
– Maintenance Schedule
– Catalogues for Engine, Alternator & AVR
Genset Optional Features
Manual & Automatic Transfer Switches,
Synchronizing & Totalizing Panels
Fuel water separator
Water jacket heater
Oil heater
Fuel heater
Battery heater
Anti-condensation Heater
Air Shut-off Valve
Oil Sampler
Pre-lube Oil Pump


- The applicable voltage range is 380V to 415V for 50Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1500 rpm.
- KT30 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT32S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA V3300-E2-BG2-GDR1 |
Cylinders & Arrangement | 4; vertical in-line |
Bore & Stroke (mm) | 98 x 110 |
Induction system | Naturally aspirated |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 22.6 |
Cooling System | Water cooled |
Displacement | 3.318 liters |
Lube oil capacity | 13.2 liters Max |
Coolant capacity | 13.2 liters |
Standard governor (Optional) | Mechanical +/-5% (Electronic) |
Engine Speed | 1500 rpm |
Fuel Consumption @ 100% Load | 7.15 (L/H) |
Fuel Consumption @ 75% Load | 5.37 (L/H) |
Fuel Consumption @ 50% Load | 3.58 (L/H) |
Fuel Consumption @ 25% Load | 1.79 (L/H) |
Radiator Cooling Air Flow (m3/s) | 0.98 |
Emissions regulations | EPA/CARB Tier 2 |
Exhaust temperature ᵒC (max) | 500 |
Max exhaust gas flow (m3/min) | 6.63 |
Max. allowed back pressure (kPa) | 7.1 |
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL042C |
Frequency / No. of poles | 50Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Coolant air flow | 0.1 m3/s |
- The complete generating set is type-tested according to ISO 8528-8 standard.

Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]§ Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]§ Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN§ Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section§ Wires are coded by printed numbers § Wires are coded by printed function of the wire |

- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355


- The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1800 rpm.
- KT33 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT37S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA V3300-E2-BG-GDR1 |
Cylinders & Arrangement | 4; vertical in-line |
Bore & Stroke (mm) | 98 x 110 |
Induction system | Turbo Charged |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 22.6 |
Cooling System | Water cooled |
Displacement | 3.318 liters |
Lube oil capacity | 13.2 liters Max |
Coolant capacity | 13.2 liters |
Standard governor (Optional) | Isochronous Electronic |
Engine Speed | 1800 rpm |
Fuel Consumption @ 100% Load | 7.9 (L/H) |
Fuel Consumption @ 75% Load | 5.925 (L/H) |
Fuel Consumption @ 50% Load | 3.95 (L/H) |
Fuel Consumption @ 25% Load | 1.975 (L/H) |
Radiator Cooling Air Flow (m3/s) | 1.22 |
Emissions regulations | EU Stage IIIA |
Exhaust temperature ᵒC (max) | 500 |
Max exhaust gas flow (m3/min) | 7.8 |
Max. allowed back pressure (kPa) | 7.1 |
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL042C |
Frequency / No. of poles | 60Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Coolant air flow | 0.13 m3/s |
- The complete generating set is type-tested according to ISO 8528-8 standard.
Control Panel Specifications
GMP260MKIII (DSE6110 MKIII) panel is an automatic
start generating set panel of microprocessor-based
design which is capable of interfacing with
electronic engine through the can-bus J1939. It is
fully configurable by PC software, yet most settings
can be programmed by front fascia buttons. If
Mains voltage is to be monitored, DSE6120MKIII
can be offered.
Circuit Breaker Schneider or ABB, 3 Pole MCB (4
Pole available as Optional)
Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]§ Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]§ Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN§ Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section§ Wires are coded by printed numbers § Wires are coded by printed function of the wire |

- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355
The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.
NOTES
- The applicable voltage range is 380V to 415V for 50Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1500 rpm.
- KT36 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT40S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA V3300-T-E2-BG2 |
Cylinders & Arrangement | 4; vertical in-line |
Bore & Stroke (mm) | 100 x 120 |
Induction system | Turbocharged |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 21.8 |
Cooling System | Water cooled |
Displacement | 3.769 liters |
Lube oil capacity | 13.2 liters Max |
Coolant capacity | 13.2 liters |
Standard governor | EPA/CARB Tier 2 |
Engine Speed | 1500 rpm |
Fuel Consumption @ 100% Load | 8.61 (L/H) |
Fuel Consumption @ 75% Load | 6.46 (L/H) |
Fuel Consumption @ 50% Load | 4.31 (L/H) |
Fuel Consumption @ 25% Load | 2.16 (L/H) |
Radiator Cooling Air Flow (m3/s) | 1.19 |
Emissions regulations | EU Stage IIIA |
Exhaust temperature ᵒC (max) | 500 |
Max exhaust gas flow (m3/min) | 9.99 |
Max. allowed back pressure (kPa) | 7.1 |
The above performance data are valid as per the following specs:
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL042F |
Frequency / No. of poles | 50Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Coolant air flow | 0.1 m3/s |
Certification
- The complete generating set is type-tested according to ISO 8528-8 standard.
Control Panel Specifications
GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939. It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.
Circuit Breaker Schneider or ABB, 3 Pole MCB (4 Pole available as Optional)
Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]
§ Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]
§ Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN
§ Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section
§ Wires are coded by printed numbers § Wires are coded by printed function of the wire |
Certification
- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355
Genset Standard Features
Assembly:
Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528-8 standard.
Fabrication:
– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.
– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.
– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.
– The control panel enclosure is made up of reliable metal sheet.
Paint:
-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.
– Paints passed durability tests conforming to international quality standards.
– Impact (EN ISO 6272)
– Salt Spray Resistance (ASTM B117-73)
– Humidity Resistance (ASTM D2247)
Works-Testing:
– All Gensets are tested prior to dispatch.
– Test is automatically generated and checked according to ISO8528
– Test certificate is issued for each Genset
Equipment:
– Water cooled Radiator with belt driven blower fan and full guarding
– Electric starter with solenoid Relay
– Battery Charging Alternator
– Energized to run solenoid
– Replaceable fuel, oil and air filters
– Heavy duty leads acid battery with matching capacity (Amps & CCA)
– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.
– Integral Fuel Tank with 67 L capacity.
Documentation:
– User Manual for Operation, Installation and Maintenance guidance
– Wring Diagram.
– Test Report
– Maintenance Schedule
– Catalogues for Engine, Alternator & AVR
Genset Optional Features
Manual & Automatic Transfer Switches,
Synchronizing & Totalizing Panels
Fuel water separator
Water jacket heater
Oil heater
Fuel heater
Battery heater
Anti-condensation Heater
Air Shut-off Valve
Oil Sampler
Pre-lube Oil Pump


- The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1800 rpm.
- KT36 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT40S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA V3300-E2-BG-GDR1 |
Cylinders & Arrangement | 4; vertical in-line |
Bore & Stroke (mm) | 98 x 110 |
Induction system | Naturally aspirated |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 22.6 |
Cooling System | Water cooled |
Displacement | 3.318 liters |
Lube oil capacity | 13.2 liters Max |
Coolant capacity | 13.2 liters |
Standard governor (Optional) | Mechanical +/-5% (Electronic) |
Engine Speed | 1800 rpm |
Fuel Consumption @ 100% Load | 7.9 (L/H) |
Fuel Consumption @ 75% Load | 5.925 (L/H) |
Fuel Consumption @ 50% Load | 3.95 (L/H) |
Fuel Consumption @ 25% Load | 1.975 (L/H) |
Radiator Cooling Air Flow (m3/s) | 1.22 |
Emissions regulations | EU Stage IIIA |
Exhaust temperature ᵒC (max) | 500 |
Max exhaust gas flow (m3/min) | 7.8 |
Max. allowed back pressure (kPa) | 7.1 |
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL042F |
Frequency / No. of poles | 60Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Coolant air flow | 0.13 m3/s |
- The complete generating set is type-tested according to ISO 8528-8 standard.

Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]§ Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]§ Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN§ Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section§ Wires are coded by printed numbers § Wires are coded by printed function of the wire |

- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355
The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.
NOTES
- The applicable voltage range is 230V for 50Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1500 rpm.
- KT37 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT40S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA V3300-T-E2-BG2 |
Cylinders & Arrangement | 4; vertical in-line |
Bore & Stroke (mm) | 100 x 120 |
Induction system | Turbocharged |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 21.8 |
Cooling System | Water cooled |
Displacement | 3.769 liters |
Lube oil capacity | 13.2 liters Max |
Coolant capacity | 13.2 liters |
Standard governor | Isochronous Electronic |
Engine Speed | 1500 rpm |
Fuel Consumption @ 100% Load | 8.61 (L/H) |
Fuel Consumption @ 75% Load | 6.46 (L/H) |
Fuel Consumption @ 50% Load | 4.31 (L/H) |
Fuel Consumption @ 25% Load | 2.16 (L/H) |
Radiator Cooling Air Flow (m3/s) | 1.19 |
Emissions regulations | EU Stage IIIA |
Exhaust temperature ᵒC (max) | 500 |
Max exhaust gas flow (m3/min) | 9.99 |
Max. allowed back pressure (kPa) | 7.1 |
The above performance data are valid as per the following specs:
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL042H |
Frequency / No. of poles | 50Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Coolant air flow | 0.1 m3/s |
Certification
- The complete generating set is type-tested according to ISO 8528-8 standard.
Control Panel Specifications
GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939. It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.
Circuit Breaker Schneider or ABB, 3 Pole MCB (4 Pole available as Optional)
Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]
§ Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]
§ Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN
§ Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section
§ Wires are coded by printed numbers § Wires are coded by printed function of the wire |
Certification
- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355
Genset Standard Features
Assembly:
Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.
Fabrication:
– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.
– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.
– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.
– The control panel enclosure is made up of reliable metal sheet.
Paint:
-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.
– Paints passed durability tests conforming to international quality standards.
– Impact (EN ISO 6272)
– Salt Spray Resistance (ASTM B117-73)
– Humidity Resistance (ASTM D2247)
Works-Testing:
– All Gensets are tested prior to dispatch.
– Test is automatically generated and checked according to ISO8528
– Test certificate is issued for each Genset
Equipment:
– Water cooled Radiator with belt driven blower fan and full guarding
– Electric starter with solenoid Relay
– Battery Charging Alternator
– Energized to run solenoid
– Replaceable fuel, oil and air filters
– Heavy duty leads acid battery with matching capacity (Amps & CCA)
– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.
– Integral Fuel Tank with 116 L capacity.
Documentation:
– User Manual for Operation, Installation and Maintenance guidance
– Wring Diagram.
– Test Report
– Maintenance Schedule
– Catalogues for Engine, Alternator & AVR
Genset Optional Features
Manual & Automatic Transfer Switches,
Synchronizing & Totalizing Panels
Fuel water separator
Water jacket heater
Oil heater
Fuel heater
Battery heater
Anti-condensation Heater
Air Shut-off Valve
Oil Sampler
Pre-lube Oil Pump
The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.
NOTES
- The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1800 rpm.
- KT44 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT49S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA V3300-T-E2-BG |
Cylinders & Arrangement | 4; vertical in-line |
Bore & Stroke (mm) | 100 x 120 |
Induction system | Turbocharged |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 21.8 |
Cooling System | Water cooled |
Displacement | 3.769 liters |
Lube oil capacity | 13.2 liters Max |
Coolant capacity | 13.2 liters |
Standard governor | Isochronous Electronic |
Engine Speed | 1800 rpm |
Fuel Consumption @ 100% Load | 9.3 (L/H) |
Fuel Consumption @ 75% Load | 6.975 (L/H) |
Fuel Consumption @ 50% Load | 4.65 (L/H) |
Fuel Consumption @ 25% Load | 2.325 (L/H) |
Radiator Cooling Air Flow (m3/s) | 1.49 |
Emissions regulations | EU Stage IIIA |
Exhaust temperature ᵒC (max) | 500 |
Max exhaust gas flow (m3/min) | 10.7 |
Max. allowed back pressure (kPa) | 7.1 |
The above performance data are valid as per the following specs:
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL042F |
Frequency / No. of poles | 60Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Coolant air flow | 0.13 m3/s |
Certification
- The complete generating set is type-tested according to ISO 8528-8 standard.
Control Panel Specifications
GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939. It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.
Circuit Breaker Schneider or ABB, 3 Pole MCB (4 Pole available as Optional)
Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]
§ Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]
§ Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN
§ Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section
§ Wires are coded by printed numbers § Wires are coded by printed function of the wire |
Certification
- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355
Genset Standard Features
Assembly:
Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.
Fabrication:
– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.
– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.
– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.
– The control panel enclosure is made up of reliable metal sheet.
Paint:
-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.
– Paints passed durability tests conforming to international quality standards.
– Impact (EN ISO 6272)
– Salt Spray Resistance (ASTM B117-73)
– Humidity Resistance (ASTM D2247)
Works-Testing:
– All Gensets are tested prior to dispatch.
– Test is automatically generated and checked according to ISO8528
– Test certificate is issued for each Genset
Equipment:
– Water cooled Radiator with belt driven blower fan and full guarding
– Electric starter with solenoid Relay
– Battery Charging Alternator
– Energized to run solenoid
– Replaceable fuel, oil and air filters
– Heavy duty leads acid battery with matching capacity (Amps & CCA)
– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.
– Integral Fuel Tank with 67 L capacity.
Documentation:
– User Manual for Operation, Installation and Maintenance guidance
– Wring Diagram.
– Test Report
– Maintenance Schedule
– Catalogues for Engine, Alternator & AVR
Genset Optional Features
Manual & Automatic Transfer Switches,
Synchronizing & Totalizing Panels
Fuel water separator
Water jacket heater
Oil heater
Fuel heater
Battery heater
Anti-condensation Heater
Air Shut-off Valve
Oil Sampler
Pre-lube Oil Pump


- The applicable voltage range is 380V to 415V for 50Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1500 rpm.
- KT45 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT48S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA V3800-T-DI-E2BG |
Cylinders & Arrangement | 4; vertical in-line |
Bore & Stroke (mm) | 100 x 120 |
Induction system | Turbocharged |
Combustion | Direct Injection |
Cycle | 4 stroke |
Compression ratio | 21.8 |
Cooling System | Water cooled |
Displacement | 3.769 liters |
Lube oil capacity | 13.2 liters Max |
Coolant capacity | 13.2 liters |
Standard governor | Electronic |
Engine Speed | 1500 rpm |
Fuel Consumption @ 100% Load | 8.61 (L/H) |
Fuel Consumption @ 75% Load | 6.46 (L/H) |
Fuel Consumption @ 50% Load | 4.31 (L/H) |
Fuel Consumption @ 25% Load | 2.16 (L/H) |
Radiator Cooling Air Flow (m3/s) | 1.19 |
Emissions regulations | EPA/CARB Tier 2 |
Exhaust temperature ᵒC (max) | 500 |
Max exhaust gas flow (m3/min) | 9.99 |
Max. allowed back pressure (kPa) | 7.1 |
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL042F |
Frequency / No. of poles | 50Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Coolant air flow | 0.1 m3/s |
- The complete generating set is type-tested according to ISO 8528-8 standard.

Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]§ Salt spray resistance [ASTM B117-73]§ Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]§ Clearance & Creepage [IEC60355-1]§ Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN§ Accuracy of 0.01mm§ Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section§ Wires are coded by printed numbers§ Wires are coded by printed function of the wire |

- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355
The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.
NOTES
- The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
- This generating set is of fixed speed of 1800 rpm.
- KT45 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
- KT49S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data | |
Make & Model | KUBOTA V3300-T-E2-BG |
Cylinders & Arrangement | 4; vertical in-line |
Bore & Stroke (mm) | 100 x 120 |
Induction system | Turbocharged |
Combustion | Indirect injection |
Cycle | 4 stroke |
Compression ratio | 21.8 |
Cooling System | Water cooled |
Displacement | 3.769 liters |
Lube oil capacity | 13.2 liters Max |
Coolant capacity | 13.2 liters |
Standard governor | Isochronous Electronic |
Engine Speed | 1800 rpm |
Fuel Consumption @ 100% Load | 9.3 (L/H) |
Fuel Consumption @ 75% Load | 6.975 (L/H) |
Fuel Consumption @ 50% Load | 4.65 (L/H) |
Fuel Consumption @ 25% Load | 2.325 (L/H) |
Radiator Cooling Air Flow (m3/s) | 1.49 |
Emissions regulations | EU Stage IIIA |
Exhaust temperature ᵒC (max) | 500 |
Max exhaust gas flow (m3/min) | 10.7 |
Max. allowed back pressure (kPa) | 7.1 |
The above performance data are valid as per the following specs:
- Diesel Fuel is according to BS2869 Class A2 or equivalent.
- Lubricating oil is according to Grade SAE 15W-40 API CI4.
- The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data | |
Make & Model | Leroy Somer TAL042H |
Frequency / No. of poles | 60Hz / 4P |
Ingress protection | IP23 |
Insulation class | H |
Terminals (Optional) | 6 (12) |
Excitation system | SHUNT |
Winding pitch | 2/3 |
AVR model | R120 |
Overspeed | 2250 R.P.M. |
Voltage regulation | ± 1 % |
Coolant air flow | 0.13 m3/s |
Certification
- The complete generating set is type-tested according to ISO 8528-8 standard.
Control Panel Specifications
GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939. It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.
Circuit Breaker Schneider or ABB, 3 Pole MCB (4 Pole available as Optional)
Construction
Sheet Fabrication | CNC shearing & bending |
Paint type | Heat-treated powder-coated |
Paint application | Electrostatic corona spraying |
Durability tests | § IMPACT [EN ISO 6272]
§ Salt spray resistance [ASTM B117-73] § Humidity Resistance [ASTM D2247] |
Compliance | § Panel is compliant with [ISO8528-8]
§ Clearance & Creepage [IEC60355-1] § Leakage current & Dielectric strength [IEC60355-1] § Protection against electric shock [IEC600 364-4-41] |
Degree of protection | IP55 |
Wire crimping | § Crimping force up to 20KN
§ Accuracy of 0.01mm § Each crimping is checked by Komax CFA+ |
Wire coding | § Wires are coded by wire color and cross-section
§ Wires are coded by printed numbers § Wires are coded by printed function of the wire |
Certification
- The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355
Genset Standard Features
Assembly:
Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.
Fabrication:
– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.
– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.
– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.
– The control panel enclosure is made up of reliable metal sheet.
Paint:
-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.
– Paints passed durability tests conforming to international quality standards.
– Impact (EN ISO 6272)
– Salt Spray Resistance (ASTM B117-73)
– Humidity Resistance (ASTM D2247)
Works-Testing:
– All Gensets are tested prior to dispatch.
– Test is automatically generated and checked according to ISO8528
– Test certificate is issued for each Genset
Equipment:
– Water cooled Radiator with belt driven blower fan and full guarding
– Electric starter with solenoid Relay
– Battery Charging Alternator
– Energized to run solenoid
– Replaceable fuel, oil and air filters
– Heavy duty leads acid battery with matching capacity (Amps & CCA)
– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.
– Integral Fuel Tank with 67 L capacity.
Documentation:
– User Manual for Operation, Installation and Maintenance guidance
– Wring Diagram.
– Test Report
– Maintenance Schedule
– Catalogues for Engine, Alternator & AVR
Genset Optional Features
Manual & Automatic Transfer Switches,
Synchronizing & Totalizing Panels
Fuel water separator
Water jacket heater
Oil heater
Fuel heater
Battery heater
Anti-condensation Heater
Air Shut-off Valve
Oil Sampler
Pre-lube Oil Pump