• Mon-Fri 7:30-16:30, Sat 7.30-13:00, Sun Closed

Ghaddar Generators powered by Cummins G-Drive engines which are the driving force behind the world’s generator sets for over 80 years, provide vital power solutions to a variety of markets including industrial, commercial, healthcare and telecommunications. Cummins G-Drive Engines fitted on Ghaddar Generators are backed by an uncompromised level of technical support and after-sales service delivered through a world-class network for complete peace of mind.

Ghaddar Generators powered by Cummins

Sort By
Categories
Sub-Categories
The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard. NOTES
  1. The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
  2. This generating set is of fixed speed of 1800 rpm.
  3. CT1150 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
  4. CT1275S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
  5. This rating level at voltage 220/380 is achieved when upsizing alternator to 2M6
Engine Technical Data
Make & Model CUMMINS QST30-G4
Cylinders & Arrangement 12, 50° Vee
Bore & Stroke (mm) 140×165 mm
Induction system Turbo Charged & Aftercooled
Combustion Direct injection
Cycle 4 stroke
Compression ratio 14.0: 1
Cooling System Water cooled
Displacement 30.5 liters
Lube oil capacity 154 liters Max
Coolant capacity 79 liters
Standard governor Electronic
Engine Speed 1800 rpm
Consumption @ 100% Load (L/H) 240
Consumption @ 75% Load (L/H) 177
Consumption @ 50% Load (L/H) 119
Consumption @ 25% Load (L/H) 66
Radiator Cooling Air Flow (m3/s) 17.07
Emissions regulations For non-regulated territories
Exhaust temperature ᵒC (max) 495
Max exhaust gas flow (m3/min) 197.1
Max. allowed back pressure (kPa) 7.0
The above performance data are valid as per the following specs:
  • Diesel Fuel is according to BS2869 Class A2 or equivalent.
  • Lubricating oil is according to Grade SAE 15W-40 API CI4.
  • The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data    
Make & Model Leroy Somer TAL049E Leroy Somer LSA50.2M6
Frequency / No. of poles 60Hz / 4P 60Hz / 4P
Ingress protection IP23 IP23
Insulation class H H
Terminals (Optional) 6 (12) 6 (12)
Excitation system SHUNT AREP
Winding pitch 2/3 2/3
AVR model R150 R450
Overspeed 2250 R.P.M. 2250 R.P.M.
Voltage regulation ± 1 % ± 1 %
Coolant air flow 1.1 m3/s 2.2 m3/s
 Certification
  • The complete generating set is type-tested according to ISO 8528-8 standard.
Control Panel Specifications GMP260MKIII (DSE6110 MKIII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939.  It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6120MKIII can be offered. Circuit Breaker Schneider or ABB, 3 Pole MCCB (4 Pole available as Optional)

Construction

Sheet Fabrication CNC shearing & bending
Paint type Heat-treated powder-coated
Paint application Electrostatic corona spraying
Durability tests §  IMPACT [EN ISO 6272]§  Salt spray resistance [ASTM B117-73] §  Humidity Resistance [ASTM D2247]
Compliance §  Panel is compliant with [ISO8528-8]§  Clearance & Creepage [IEC60355-1] §  Leakage current & Dielectric strength [IEC60355-1] §  Protection against electric shock [IEC600 364-4-41]
Degree of protection IP55
Wire crimping §  Crimping force up to 20KN§  Accuracy of 0.01mm §  Each crimping is checked by Komax CFA+
Wire coding §  Wires are coded by wire color and cross-section§  Wires are coded by printed numbers §  Wires are coded by printed function of the wire
Certification
  • The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355
Genset Standard Features Assembly: Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard. Fabrication: – The engine/alternator assembly rests on skid with Anti-vibration mounting pads. – The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms. – A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses. – The control panel enclosure is made up of reliable metal sheet. Paint: -The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying. – Paints passed durability tests conforming to international quality standards. – Impact (EN ISO 6272) – Salt Spray Resistance (ASTM B117-73) – Humidity Resistance (ASTM D2247) Works-Testing: – All Gensets are tested prior to dispatch. – Test is automatically generated and checked according to ISO8528 – Test certificate is issued for each Genset Equipment: – Water cooled Radiator with belt driven blower fan and full guarding – Electric starter with solenoid Relay – Battery Charging Alternator – Energized to run solenoid – Replaceable fuel, oil and air filters – Heavy duty leads acid battery with matching capacity (Amps & CCA) – One loose supplied industrial exhaust silencer – 16 DB noise reduction level. Documentation: – User Manual for Operation, Installation and Maintenance guidance – Wring Diagram. – Test Report – Maintenance Schedule – Catalogues for Engine, Alternator & AVR Genset Optional Features Manual & Automatic Transfer Switches, Synchronizing & Totalizing Panels Fuel water separator Water jacket heater Oil heater Fuel heater Battery heater Anti-condensation Heater Air Shut-off Valve Oil Sampler Pre-lube Oil Pump

 

 

 

The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.

NOTES

  1. The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
  2. This generating set is of fixed speed of 1800 rpm.
  3. CT1155 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
  4. CT1265S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
  5. This rating level at voltage 220/380 is achieved when upsizing alternator to 2M6
Engine Technical Data
Make & Model CUMMINS KTA38-G4
Cylinders & Arrangement 12, 60° Vee
Bore & Stroke (mm) 159×159 mm
Induction system Turbo Charged & Aftercooled
Combustion Direct injection
Cycle 4 stroke
Compression ratio 13.9: 1
Cooling System Water cooled
Displacement 37.8 liters
Lube oil capacity 135 liters Max
Coolant capacity 124 liters
Standard governor Electronic
Engine Speed 1800 rpm
Consumption @ 100% Load (L/H) 245
Consumption @ 75% Load (L/H) 190
Consumption @ 50% Load (L/H) 136
Consumption @ 25% Load (L/H) 81
Radiator Cooling Air Flow (m3/s) 24.6
Emissions regulations For non-regulated territories
Exhaust temperature ᵒC (max) 499
Max exhaust gas flow (m3/min) 218.5
Max. allowed back pressure (kPa) 10.0

The above performance data are valid as per the following specs:

  • Diesel Fuel is according to BS2869 Class A2 or equivalent.
  • Lubricating oil is according to Grade SAE 15W-40 API CI4.
  • The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data    
Make & Model Leroy Somer TAL049E Leroy Somer LSA50.2M6
Frequency / No. of poles 60Hz / 4P 60Hz / 4P
Ingress protection IP23 IP23
Insulation class H H
Terminals (Optional) 6 (12) 6 (12)
Excitation system SHUNT AREP
Winding pitch 2/3 2/3
AVR model R150 R450
Overspeed 2250 R.P.M. 2250 R.P.M.
Voltage regulation ± 1 % ± 0.5 %
Coolant air flow 1.1 m3/s 2.2 m3/s

 Certification

  • The complete generating set is type-tested according to ISO 8528-8 standard.

 

Control Panel Specifications

GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939.  It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.

Circuit Breaker Schneider or ABB, 3 Pole MCCB (4 Pole available as Optional)

Construction

Sheet Fabrication CNC shearing & bending
Paint type Heat-treated powder-coated
Paint application Electrostatic corona spraying
Durability tests §  IMPACT [EN ISO 6272]

§  Salt spray resistance [ASTM B117-73]

§  Humidity Resistance [ASTM D2247]

Compliance §  Panel is compliant with [ISO8528-8]

§  Clearance & Creepage [IEC60355-1]

§  Leakage current & Dielectric strength [IEC60355-1]

§  Protection against electric shock [IEC600 364-4-41]

Degree of protection IP55
Wire crimping §  Crimping force up to 20KN

§  Accuracy of 0.01mm

§  Each crimping is checked by Komax CFA+

Wire coding §  Wires are coded by wire color and cross-section

§  Wires are coded by printed numbers

§  Wires are coded by printed function of the wire

Certification

  • The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355

Genset Standard Features

Assembly:

Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.

Fabrication:

– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.

– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.

– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.

– The control panel enclosure is made up of reliable metal sheet.

Paint:

-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.

– Paints passed durability tests conforming to international quality standards.

– Impact (EN ISO 6272)

– Salt Spray Resistance (ASTM B117-73)

– Humidity Resistance (ASTM D2247)

Works-Testing:

– All Gensets are tested prior to dispatch.

– Test is automatically generated and checked according to ISO8528

– Test certificate is issued for each Genset

Equipment:

– Water cooled Radiator with belt driven blower fan and full guarding

– Electric starter with solenoid Relay

– Battery Charging Alternator

– Energized to run solenoid

– Replaceable fuel, oil and air filters

– Heavy duty leads acid battery with matching capacity (Amps & CCA)

– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.

Documentation:

– User Manual for Operation, Installation and Maintenance guidance

– Wring Diagram.

– Test Report

– Maintenance Schedule

– Catalogues for Engine, Alternator & AVR

Genset Optional Features

Manual & Automatic Transfer Switches,

Synchronizing & Totalizing Panels

Fuel water separator

Water jacket heater

Oil heater

Fuel heater

Battery heater

Anti-condensation Heater

Air Shut-off Valve

Oil Sampler

Pre-lube Oil Pump

 

 

 

The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.

 NOTES

  1. The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
  2. This generating set is of fixed speed of 1800 rpm.
  3. CT1285 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
  4. CT1410S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data
Make & Model CUMMINS KTA50-G3
Cylinders & Arrangement 16, 60° Vee
Bore & Stroke (mm) 159×159 mm
Induction system Turbo Charged & Aftercooled
Combustion Direct injection
Cycle 4 stroke
Compression ratio 13.9: 1
Cooling System Water cooled
Displacement 50.3 liters
Lube oil capacity 177 liters Max
Coolant capacity 161 liters
Standard governor Electronic
Engine Speed 1800 rpm
Consumption @ 100% Load (L/H) 291
Consumption @ 75% Load (L/H) 222
Consumption @ 50% Load (L/H) 157
Consumption @ 25% Load (L/H) 89
Radiator Cooling Air Flow (m3/s) 34.6
Emissions regulations For non-regulated territories
Exhaust temperature ᵒC (max) 460
Max exhaust gas flow (m3/min) 237.8
Max. allowed back pressure (kPa) 7.0

The above performance data are valid as per the following specs:

  • Diesel Fuel is according to BS2869 Class A2 or equivalent.
  • Lubricating oil is according to Grade SAE 15W-40 API CI4.
  • The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data  
Make & Model Leroy Somer LSA50.2M6
Frequency / No. of poles 60Hz / 4P
Ingress protection IP23
Insulation class H
Terminals (Optional) 6 (12)
Excitation system AREP
Winding pitch 2/3
AVR model R450
Overspeed 2250 R.P.M.
Voltage regulation ± 0.5 %
Coolant air flow 2.2 m3/s

 Certification

  • The complete generating set is type-tested according to ISO 8528-8 standard.

 

Control Panel Specifications

GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939.  It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.

Circuit Breaker Schneider or ABB, 3 Pole ACB (4 Pole available as Optional)

Construction

Sheet Fabrication CNC shearing & bending
Paint type Heat-treated powder-coated
Paint application Electrostatic corona spraying
Durability tests §  IMPACT [EN ISO 6272]

§  Salt spray resistance [ASTM B117-73]

§  Humidity Resistance [ASTM D2247]

Compliance §  Panel is compliant with [ISO8528-8]

§  Clearance & Creepage [IEC60355-1]

§  Leakage current & Dielectric strength [IEC60355-1]

§  Protection against electric shock [IEC600 364-4-41]

Degree of protection IP55
Wire crimping §  Crimping force up to 20KN

§  Accuracy of 0.01mm

§  Each crimping is checked by Komax CFA+

Wire coding §  Wires are coded by wire color and cross-section

§  Wires are coded by printed numbers

§  Wires are coded by printed function of the wire

Certification

  • The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355

Genset Standard Features

Assembly:

Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.

Fabrication:

– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.

– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.

– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.

– The control panel enclosure is made up of reliable metal sheet.

Paint:

-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.

– Paints passed durability tests conforming to international quality standards.

– Impact (EN ISO 6272)

– Salt Spray Resistance (ASTM B117-73)

– Humidity Resistance (ASTM D2247)

Works-Testing:

– All Gensets are tested prior to dispatch.

– Test is automatically generated and checked according to ISO8528

– Test certificate is issued for each Genset

Equipment:

– Water cooled Radiator with belt driven blower fan and full guarding

– Electric starter with solenoid Relay

– Battery Charging Alternator

– Energized to run solenoid

– Replaceable fuel, oil and air filters

– Heavy duty leads acid battery with matching capacity (Amps & CCA)

– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.

Documentation:

– User Manual for Operation, Installation and Maintenance guidance

– Wring Diagram.

– Test Report

– Maintenance Schedule

– Catalogues for Engine, Alternator & AVR

Genset Optional Features

Manual & Automatic Transfer Switches,

Synchronizing & Totalizing Panels

Fuel water separator

Water jacket heater

Oil heater

Fuel heater

Battery heater

Anti-condensation Heater

Air Shut-off Valve

Oil Sampler

Pre-lube Oil Pump

 

 

 

 

The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.

NOTES

  1. The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
  2. This generating set is of fixed speed of 1800 rpm.
  3. CT1410 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
  4. CT1585S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data
Make & Model CUMMINS KTA50-G3
Cylinders & Arrangement 16, 60° Vee
Bore & Stroke (mm) 159×159 mm
Induction system Turbo Charged & Aftercooled
Combustion Direct injection
Cycle 4 stroke
Compression ratio 13.9: 1
Cooling System Water cooled
Displacement 50.3 liters
Lube oil capacity 177 liters Max
Coolant capacity 161 liters
Standard governor Electronic
Engine Speed 1800 rpm
Consumption @ 100% Load (L/H) 291
Consumption @ 75% Load (L/H) 222
Consumption @ 50% Load (L/H) 157
Consumption @ 25% Load (L/H) 89
Radiator Cooling Air Flow (m3/s) 34.6
Emissions regulations For non-regulated territories
Exhaust temperature ᵒC (max) 460
Max exhaust gas flow (m3/min) 237.8
Max. allowed back pressure (kPa) 7.0

The above performance data are valid as per the following specs:

  • Diesel Fuel is according to BS2869 Class A2 or equivalent.
  • Lubricating oil is according to Grade SAE 15W-40 API CI4.
  • The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data  
Make & Model Leroy Somer LSA50.2L8
Frequency / No. of poles 60Hz / 4P
Ingress protection IP23
Insulation class H
Terminals (Optional) 6 (12)
Excitation system AREP
Winding pitch 2/3
AVR model R450
Overspeed 2250 R.P.M.
Voltage regulation ± 0.5 %
Coolant air flow 2.2 m3/s

 Certification

  • The complete generating set is type-tested according to ISO 8528-8 standard.

 

Control Panel Specifications

GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939.  It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.

Circuit Breaker Schneider or ABB, 3 Pole ACB (4 Pole available as Optional)

Construction

Sheet Fabrication CNC shearing & bending
Paint type Heat-treated powder-coated
Paint application Electrostatic corona spraying
Durability tests §  IMPACT [EN ISO 6272]

§  Salt spray resistance [ASTM B117-73]

§  Humidity Resistance [ASTM D2247]

Compliance §  Panel is compliant with [ISO8528-8]

§  Clearance & Creepage [IEC60355-1]

§  Leakage current & Dielectric strength [IEC60355-1]

§  Protection against electric shock [IEC600 364-4-41]

Degree of protection IP55
Wire crimping §  Crimping force up to 20KN

§  Accuracy of 0.01mm

§  Each crimping is checked by Komax CFA+

Wire coding §  Wires are coded by wire color and cross-section

§  Wires are coded by printed numbers

§  Wires are coded by printed function of the wire

Certification

  • The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355

Genset Standard Features

Assembly:

Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.

Fabrication:

– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.

– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.

– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.

– The control panel enclosure is made up of reliable metal sheet.

Paint:

-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.

– Paints passed durability tests conforming to international quality standards.

– Impact (EN ISO 6272)

– Salt Spray Resistance (ASTM B117-73)

– Humidity Resistance (ASTM D2247)

Works-Testing:

– All Gensets are tested prior to dispatch.

– Test is automatically generated and checked according to ISO8528

– Test certificate is issued for each Genset

Equipment:

– Water cooled Radiator with belt driven blower fan and full guarding

– Electric starter with solenoid Relay

– Battery Charging Alternator

– Energized to run solenoid

– Replaceable fuel, oil and air filters

– Heavy duty leads acid battery with matching capacity (Amps & CCA)

– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.

Documentation:

– User Manual for Operation, Installation and Maintenance guidance

– Wring Diagram.

– Test Report

– Maintenance Schedule

– Catalogues for Engine, Alternator & AVR

Genset Optional Features

Manual & Automatic Transfer Switches,

Synchronizing & Totalizing Panels

Fuel water separator

Water jacket heater

Oil heater

Fuel heater

Battery heater

Anti-condensation Heater

Air Shut-off Valve

Oil Sampler

Pre-lube Oil Pump

 

 

 

 

The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.

NOTES

  1. The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
  2. This generating set is of fixed speed of 1800 rpm.
  3. CT150 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
  4. CT165S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
  5. This rating level at voltage 220/380 is achieved when upsizing alternator to TAL044J
Engine Technical Data
Make & Model CUMMINS  6BTAA5.9-G6
Cylinders & Arrangement 6; in-line
Bore & Stroke (mm) 120×120 mm
Induction system Turbo Charged & Aftercooled
Combustion Direct injection
Cycle 4 stroke
Compression ratio 16.5: 1
Cooling System Water cooled
Displacement 5.9 liters
Lube oil capacity 16.4 liters Max
Coolant capacity  21 liters
Standard governor Electronic
Engine Speed 1800 rpm
Consumption @ 100% Load (L/H) 36.46
Consumption @ 75% Load (L/H) 31.47
Consumption @ 50% Load (L/H) 20.71
Consumption @ 25% Load (L/H) 11.71
Radiator Cooling Air Flow (m3/s) 3.7
Emissions regulations For non-regulated territories
Exhaust temperature ᵒC (max) 462
Max exhaust gas flow (m3/min) 29.2
Max. allowed back pressure (kPa) 10.25

The above performance data are valid as per the following specs:

  • Diesel Fuel is according to BS2869 Class A2 or equivalent.
  • Lubricating oil is according to Grade SAE 15W-40 API CI4.
  • The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data    
Make & Model Leroy Somer TAL044H Leroy Somer TAL044J
Frequency / No. of poles 60Hz / 4P 60Hz / 4P
Ingress protection IP23 IP23
Insulation class H H
Terminals (Optional) 6 (12) 6 (12)
Excitation system SHUNT SHUNT
Winding pitch 2/3 2/3
AVR model R120 R120
Overspeed 2250 R.P.M. 2250 R.P.M.
Voltage regulation ± 1 % ± 1 %
Coolant air flow 0.3 m3/s 0.3 m3/s

 Certification

  • The complete generating set is type-tested according to ISO 8528-8 standard.

 

Control Panel Specifications

GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939.  It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.

Circuit Breaker Schneider or ABB, 3 Pole MCCB (4 Pole available as Optional)

Construction

Sheet Fabrication CNC shearing & bending
Paint type Heat-treated powder-coated
Paint application Electrostatic corona spraying
Durability tests §  IMPACT [EN ISO 6272]

§  Salt spray resistance [ASTM B117-73]

§  Humidity Resistance [ASTM D2247]

Compliance §  Panel is compliant with [ISO8528-8]

§  Clearance & Creepage [IEC60355-1]

§  Leakage current & Dielectric strength [IEC60355-1]

§  Protection against electric shock [IEC600 364-4-41]

Degree of protection IP55
Wire crimping §  Crimping force up to 20KN

§  Accuracy of 0.01mm

§  Each crimping is checked by Komax CFA+

Wire coding §  Wires are coded by wire color and cross-section

§  Wires are coded by printed numbers

§  Wires are coded by printed function of the wire

Certification

  • The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355

Genset Standard Features

Assembly:

Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.

Fabrication:

– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.

– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.

– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.

– The control panel enclosure is made up of reliable metal sheet.

Paint:

-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.

– Paints passed durability tests conforming to international quality standards.

– Impact (EN ISO 6272)

– Salt Spray Resistance (ASTM B117-73)

– Humidity Resistance (ASTM D2247)

Works-Testing:

– All Gensets are tested prior to dispatch.

– Test is automatically generated and checked according to ISO8528

– Test certificate is issued for each Genset

Equipment:

– Water cooled Radiator with belt driven blower fan and full guarding

– Electric starter with solenoid Relay

– Battery Charging Alternator

– Energized to run solenoid

– Replaceable fuel, oil and air filters

– Heavy duty leads acid battery with matching capacity (Amps & CCA)

– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.

– Integral Fuel Tank with 150 L capacity.

Documentation:

– User Manual for Operation, Installation and Maintenance guidance

– Wring Diagram.

– Test Report

– Maintenance Schedule

– Catalogues for Engine, Alternator & AVR

Genset Optional Features

Manual & Automatic Transfer Switches,

Synchronizing & Totalizing Panels

Fuel water separator

Water jacket heater

Oil heater

Fuel heater

Battery heater

Anti-condensation Heater

Air Shut-off Valve

Oil Sampler

Pre-lube Oil Pump

 

 

 

 

The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.

 NOTES

  1. The applicable voltage is 220V for 60Hz applications. For other voltages, please consult factory.
  2. This generating set is of fixed speed of 1800 rpm.
  3. CT1615 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
  4. CT1800S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data
Make & Model CUMMINS KTA50-G9
Cylinders & Arrangement 16, 60° Vee
Bore & Stroke (mm) 159×159 mm
Induction system Turbo Charged & Aftercooled
Combustion Direct injection
Cycle 4 stroke
Compression ratio 13.9: 1
Cooling System Water cooled
Displacement 50.3 liters
Lube oil capacity 178 liters Max
Coolant capacity 174 liters
Standard governor Electronic
Engine Speed 1800 rpm
Consumption @ 100% Load (L/H) 330
Consumption @ 75% Load (L/H) 257
Consumption @ 50% Load (L/H) 180
Consumption @ 25% Load (L/H) 111
Radiator Cooling Air Flow (m3/s) 28
Emissions regulations For non-regulated territories
Exhaust temperature ᵒC (max) 460
Max exhaust gas flow (m3/min) 237.8
Max. allowed back pressure (kPa) 6.8

The above performance data are valid as per the following specs:

  • Diesel Fuel is according to BS2869 Class A2 or equivalent.
  • Lubricating oil is according to Grade SAE 15W-40 API CI4.
  • The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data  
Make & Model Leroy Somer LSA50.2VL10
Frequency / No. of poles 60Hz / 4P
Ingress protection IP23
Insulation class H
Terminals (Optional) 6 (12)
Excitation system AREP (PMG)
Winding pitch 2/3
AVR model R450
Overspeed 2250 R.P.M.
Voltage regulation ± 0.5 %
Coolant air flow 2.2 m3/s

 Certification

  • The complete generating set is type-tested according to ISO 8528-8 standard.

 

Control Panel Specifications

GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939.  It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.

Circuit Breaker Schneider or ABB, 3 Pole ACB (4 Pole available as Optional)

Construction

Sheet Fabrication CNC shearing & bending
Paint type Heat-treated powder-coated
Paint application Electrostatic corona spraying
Durability tests §  IMPACT [EN ISO 6272]

§  Salt spray resistance [ASTM B117-73]

§  Humidity Resistance [ASTM D2247]

Compliance §  Panel is compliant with [ISO8528-8]

§  Clearance & Creepage [IEC60355-1]

§  Leakage current & Dielectric strength [IEC60355-1]

§  Protection against electric shock [IEC600 364-4-41]

Degree of protection IP55
Wire crimping §  Crimping force up to 20KN

§  Accuracy of 0.01mm

§  Each crimping is checked by Komax CFA+

Wire coding §  Wires are coded by wire color and cross-section

§  Wires are coded by printed numbers

§  Wires are coded by printed function of the wire

Certification

  • The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355

Genset Standard Features

Assembly:

Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.

Fabrication:

– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.

– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.

– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.

– The control panel enclosure is made up of reliable metal sheet.

Paint:

-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.

– Paints passed durability tests conforming to international quality standards.

– Impact (EN ISO 6272)

– Salt Spray Resistance (ASTM B117-73)

– Humidity Resistance (ASTM D2247)

Works-Testing:

– All Gensets are tested prior to dispatch.

– Test is automatically generated and checked according to ISO8528

– Test certificate is issued for each Genset

Equipment:

– Water cooled Radiator with belt driven blower fan and full guarding

– Electric starter with solenoid Relay

– Battery Charging Alternator

– Energized to run solenoid

– Replaceable fuel, oil and air filters

– Heavy duty leads acid battery with matching capacity (Amps & CCA)

– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.

Documentation:

– User Manual for Operation, Installation and Maintenance guidance

– Wring Diagram.

– Test Report

– Maintenance Schedule

– Catalogues for Engine, Alternator & AVR

Genset Optional Features

Manual & Automatic Transfer Switches,

Synchronizing & Totalizing Panels

Fuel water separator

Water jacket heater

Oil heater

Fuel heater

Battery heater

Anti-condensation Heater

Air Shut-off Valve

Oil Sampler

Pre-lube Oil Pump

 

 

 

The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.

NOTES

  1. The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
  2. This generating set is of fixed speed of 1800 rpm.
  3. CT225 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
  4. CT250S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
  5. This rating level at voltage 220/380 is achieved when upsizing alternator to TAL046C
Engine Technical Data
Make & Model CUMMINS QSB7-G5
Cylinders & Arrangement 6; in-line
Bore & Stroke (mm) 107×124 mm
Induction system Turbo Charged & Aftercooled
Combustion Direct injection
Cycle 4 stroke
Compression ratio 17.2: 1
Cooling System Water cooled
Displacement 6.7 liters
Lube oil capacity 18.9 liters Max
Coolant capacity 10.2 liters
Standard governor Electronic
Engine Speed 1800 rpm
Consumption @ 100% Load (L/H) 50
Consumption @ 75% Load (L/H) 40
Consumption @ 50% Load (L/H) 30
Consumption @ 25% Load (L/H) 15
Radiator Cooling Air Flow (m3/s) 6.32
Emissions regulations For non-regulated territories
Exhaust temperature ᵒC (max) 487
Max exhaust gas flow (m3/min) 38.0
Max. allowed back pressure (kPa) 10.2

The above performance data are valid as per the following specs:

  • Diesel Fuel is according to BS2869 Class A2 or equivalent.
  • Lubricating oil is according to Grade SAE 15W-40 API CI4.
  • The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data    
Make & Model Leroy Somer TAL046B Leroy Somer TAL046C
Frequency / No. of poles 60Hz / 4P 60Hz / 4P
Ingress protection IP23 IP23
Insulation class H H
Terminals (Optional) 6 (12) 6 (12)
Excitation system SHUNT SHUNT
Winding pitch 2/3 2/3
AVR model R150 R150
Overspeed 2250 R.P.M. 2250 R.P.M.
Voltage regulation ± 1 % ± 1 %
Coolant air flow 0.58 m3/s 0.58 m3/s

 Certification

  • The complete generating set is type-tested according to ISO 8528-8 standard.

 

Control Panel Specifications

GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939.  It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.

Circuit Breaker Schneider or ABB, 3 Pole MCCB (4 Pole available as Optional)

Construction

Sheet Fabrication CNC shearing & bending
Paint type Heat-treated powder-coated
Paint application Electrostatic corona spraying
Durability tests §  IMPACT [EN ISO 6272]

§  Salt spray resistance [ASTM B117-73]

§  Humidity Resistance [ASTM D2247]

Compliance §  Panel is compliant with [ISO8528-8]

§  Clearance & Creepage [IEC60355-1]

§  Leakage current & Dielectric strength [IEC60355-1]

§  Protection against electric shock [IEC600 364-4-41]

Degree of protection IP55
Wire crimping §  Crimping force up to 20KN

§  Accuracy of 0.01mm

§  Each crimping is checked by Komax CFA+

Wire coding §  Wires are coded by wire color and cross-section

§  Wires are coded by printed numbers

§  Wires are coded by printed function of the wire

Certification

  • The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355

Genset Standard Features

Assembly:

Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.

Fabrication:

– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.

– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.

– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.

– The control panel enclosure is made up of reliable metal sheet.

Paint:

-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.

– Paints passed durability tests conforming to international quality standards.

– Impact (EN ISO 6272)

– Salt Spray Resistance (ASTM B117-73)

– Humidity Resistance (ASTM D2247)

Works-Testing:

– All Gensets are tested prior to dispatch.

– Test is automatically generated and checked according to ISO8528

– Test certificate is issued for each Genset

Equipment:

– Water cooled Radiator with belt driven blower fan and full guarding

– Electric starter with solenoid Relay

– Battery Charging Alternator

– Energized to run solenoid

– Replaceable fuel, oil and air filters

– Heavy duty leads acid battery with matching capacity (Amps & CCA)

– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.

– Integral Fuel Tank with 297 L capacity.

Documentation:

– User Manual for Operation, Installation and Maintenance guidance

– Wring Diagram.

– Test Report

– Maintenance Schedule

– Catalogues for Engine, Alternator & AVR

Genset Optional Features

Manual & Automatic Transfer Switches,

Synchronizing & Totalizing Panels

Fuel water separator

Water jacket heater

Oil heater

Fuel heater

Battery heater

Anti-condensation Heater

Air Shut-off Valve

Oil Sampler

Pre-lube Oil Pump

 

 

 

 

The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.

NOTES

  1. The applicable voltage is 220V for 60Hz applications. For other voltages, please consult factory.
  2. This generating set is of fixed speed of 1800 rpm.
  3. CT2300 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
  4. CT2530S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data
Make & Model CUMMINS QSK60-G6
Cylinders & Arrangement 16, 60° Vee
Bore & Stroke (mm) 159×190 mm
Induction system Turbo Charged & Aftercooled
Combustion Direct injection
Cycle 4 stroke
Compression ratio 14.5: 1
Cooling System Water cooled
Displacement 60.2 liters
Lube oil capacity 280 liters Max
Coolant capacity 490 liters
Standard governor Electronic
Engine Speed 1800 rpm
Consumption @ 100% Load (L/H) 466
Consumption @ 75% Load (L/H) 356
Consumption @ 50% Load (L/H) 247
Consumption @ 25% Load (L/H) 144
Radiator Cooling Air Flow (m3/s) 34
Emissions regulations For non-regulated territories
Exhaust temperature ᵒC (max) 460
Max exhaust gas flow (m3/min) 399
Max. allowed back pressure (kPa) 6.8

The above performance data are valid as per the following specs:

  • Diesel Fuel is according to BS2869 Class A2 or equivalent.
  • Lubricating oil is according to Grade SAE 15W-40 API CI4.
  • The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data  
Make & Model Leroy Somer LSA52.3S6 (8S)
Frequency / No. of poles 60Hz / 4P
Ingress protection IP23
Insulation class H
Terminals (Optional) 6
Excitation system AREP + PMI
Winding pitch 2/3
AVR model D 510C
Overspeed 2250 R.P.M.
Voltage regulation ± 0.5 %
Coolant air flow 2.8 m3/s

 Certification

  • The complete generating set is type-tested according to ISO 8528-8 standard.

 

Control Panel Specifications

GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939.  It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.

Circuit Breaker Schneider or ABB, 3 Pole ACB (4 Pole available as Optional)

Construction

Sheet Fabrication CNC shearing & bending
Paint type Heat-treated powder-coated
Paint application Electrostatic corona spraying
Durability tests §  IMPACT [EN ISO 6272]

§  Salt spray resistance [ASTM B117-73]

§  Humidity Resistance [ASTM D2247]

Compliance §  Panel is compliant with [ISO8528-8]

§  Clearance & Creepage [IEC60355-1]

§  Leakage current & Dielectric strength [IEC60355-1]

§  Protection against electric shock [IEC600 364-4-41]

Degree of protection IP55
Wire crimping §  Crimping force up to 20KN

§  Accuracy of 0.01mm

§  Each crimping is checked by Komax CFA+

Wire coding §  Wires are coded by wire color and cross-section

§  Wires are coded by printed numbers

§  Wires are coded by printed function of the wire

Certification

  • The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355

Genset Standard Features

Assembly:

Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard. 

Fabrication:

– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.

– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.

– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.

– The control panel enclosure is made up of reliable metal sheet.

Paint:

-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.

– Paints passed durability tests conforming to international quality standards.

– Impact (EN ISO 6272)

– Salt Spray Resistance (ASTM B117-73)

– Humidity Resistance (ASTM D2247)

Works-Testing:

– All Gensets are tested prior to dispatch.

– Test is automatically generated and checked according to ISO8528

– Test certificate is issued for each Genset

Equipment:

– Water cooled Radiator with belt driven blower fan and full guarding

– Electric starter with solenoid Relay

– Battery Charging Alternator

– Energized to run solenoid

– Replaceable fuel, oil and air filters

– Heavy duty leads acid battery with matching capacity (Amps & CCA)

– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.

Documentation:

– User Manual for Operation, Installation and Maintenance guidance

– Wring Diagram.

– Test Report

– Maintenance Schedule

– Catalogues for Engine, Alternator & AVR

Genset Optional Features

Manual & Automatic Transfer Switches,

Synchronizing & Totalizing Panels

Fuel water separator

Water jacket heater

Oil heater

Fuel heater

Battery heater

Anti-condensation Heater

Air Shut-off Valve

Oil Sampler

Pre-lube Oil Pump

 

 

 

The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.

NOTES

  1. The applicable voltage is 220V for 60Hz applications. For other voltages, please consult factory.
  2. This generating set is of fixed speed of 1800 rpm.
  3. CT2850 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
  4. CT3150S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data
Make & Model CUMMINS QSK78-G7
Cylinders & Arrangement 18, 60° Vee
Bore & Stroke (mm) 170×190 mm
Induction system Turbo Charged & Aftercooled
Combustion Direct injection
Cycle 4 stroke
Compression ratio 15.3: 1
Cooling System Water cooled
Displacement 77.6 liters
Lube oil capacity 465.6 liters Max
Coolant capacity 223.4 liters
Standard governor Electronic
Engine Speed 1800 rpm
Consumption @ 100% Load (L/H) 611
Consumption @ 75% Load (L/H) 475
Consumption @ 50% Load (L/H) 345
Consumption @ 25% Load (L/H) 201
Radiator Cooling Air Flow (m3/s) TBA
Emissions regulations For non-regulated territories
Exhaust temperature ᵒC (max) 433
Max exhaust gas flow (m3/min) 536.1
Max. allowed back pressure (kPa) 7.0

The above performance data are valid as per the following specs:

  • Diesel Fuel is according to BS2869 Class A2 or equivalent.
  • Lubricating oil is according to Grade SAE 15W-40 API CI4.
  • The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data  
Make & Model Leroy Somer LSA52.3L12 (8S)
Frequency / No. of poles 60Hz / 4P
Ingress protection IP23
Insulation class H
Terminals (Optional) 6
Excitation system AREP + PMI
Winding pitch 2/3
AVR model D 510C
Overspeed 2250 R.P.M.
Voltage regulation ± 0.5 %
Coolant air flow 2.8 m3/s

 Certification

  • The complete generating set is type-tested according to ISO 8528-8 standard.

 

Control Panel Specifications

GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939.  It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.

Circuit Breaker Schneider or ABB, 3 Pole ACB (4 Pole available as Optional)

Construction

Sheet Fabrication CNC shearing & bending
Paint type Heat-treated powder-coated
Paint application Electrostatic corona spraying
Durability tests §  IMPACT [EN ISO 6272]

§  Salt spray resistance [ASTM B117-73]

§  Humidity Resistance [ASTM D2247]

Compliance §  Panel is compliant with [ISO8528-8]

§  Clearance & Creepage [IEC60355-1]

§  Leakage current & Dielectric strength [IEC60355-1]

§  Protection against electric shock [IEC600 364-4-41]

Degree of protection IP55
Wire crimping §  Crimping force up to 20KN

§  Accuracy of 0.01mm

§  Each crimping is checked by Komax CFA+

Wire coding §  Wires are coded by wire color and cross-section

§  Wires are coded by printed numbers

§  Wires are coded by printed function of the wire

Certification

  • The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355

Genset Standard Features 

Assembly:

Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.

Fabrication:

– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.

– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.

– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.

– The control panel enclosure is made up of reliable metal sheet.

Paint:

-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.

– Paints passed durability tests conforming to international quality standards.

– Impact (EN ISO 6272)

– Salt Spray Resistance (ASTM B117-73)

– Humidity Resistance (ASTM D2247)

Works-Testing:

– All Gensets are tested prior to dispatch.

– Test is automatically generated and checked according to ISO8528

– Test certificate is issued for each Genset

Equipment:

– Water cooled Radiator with belt driven blower fan and full guarding

– Electric starter with solenoid Relay

– Battery Charging Alternator

– Energized to run solenoid

– Replaceable fuel, oil and air filters

– Heavy duty leads acid battery with matching capacity (Amps & CCA)

– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.

Documentation:

– User Manual for Operation, Installation and Maintenance guidance

– Wring Diagram.

– Test Report

– Maintenance Schedule

– Catalogues for Engine, Alternator & AVR

Genset Optional Features

Manual & Automatic Transfer Switches,

Synchronizing & Totalizing Panels

Fuel water separator

Water jacket heater

Oil heater

Fuel heater

Battery heater

Anti-condensation Heater

Air Shut-off Valve

Oil Sampler

Pre-lube Oil Pump

 

 

 

The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.

NOTES

  1. The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
  2. This generating set is of fixed speed of 1800 rpm.
  3. CT290 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
  4. CT320S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data
Make & Model CUMMINS QSL9-G3
Cylinders & Arrangement 6; in-line
Bore & Stroke (mm) 114×145 mm
Induction system Turbo Charged & Aftercooled
Combustion Direct injection
Cycle 4 stroke
Compression ratio 17.8: 1
Cooling System Water cooled
Displacement 8.8 liters
Lube oil capacity 26.5 liters Max
Coolant capacity 11.0 liters
Standard governor Electronic
Engine Speed 1800 rpm
Consumption @ 100% Load (L/H) 70
Consumption @ 75% Load (L/H) 58
Consumption @ 50% Load (L/H) 41
Consumption @ 25% Load (L/H) 21
Radiator Cooling Air Flow (m3/s) 8.0
Emissions regulations For non-regulated territories
Exhaust temperature ᵒC (max) 560
Max exhaust gas flow (m3/min) 57.9
Max. allowed back pressure (kPa) 10.2

The above performance data are valid as per the following specs:

  • Diesel Fuel is according to BS2869 Class A2 or equivalent.
  • Lubricating oil is according to Grade SAE 15W-40 API CI4.
  • The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data  
Make & Model Leroy Somer TAL046F
Frequency / No. of poles 60Hz / 4P
Ingress protection IP23
Insulation class H
Terminals (Optional) 6 (12)
Excitation system SHUNT
Winding pitch 2/3
AVR model R150
Overspeed 2250 R.P.M.
Voltage regulation ± 1 %
Coolant air flow 0.58 m3/s

 Certification

  • The complete generating set is type-tested according to ISO 8528-8 standard.

 

Control Panel Specifications

GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939.  It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.

Circuit Breaker Schneider or ABB, 3 Pole MCCB (4 Pole available as Optional)

Construction

Sheet Fabrication CNC shearing & bending
Paint type Heat-treated powder-coated
Paint application Electrostatic corona spraying
Durability tests §  IMPACT [EN ISO 6272]

§  Salt spray resistance [ASTM B117-73]

§  Humidity Resistance [ASTM D2247]

Compliance §  Panel is compliant with [ISO8528-8]

§  Clearance & Creepage [IEC60355-1]

§  Leakage current & Dielectric strength [IEC60355-1]

§  Protection against electric shock [IEC600 364-4-41]

Degree of protection IP55
Wire crimping §  Crimping force up to 20KN

§  Accuracy of 0.01mm

§  Each crimping is checked by Komax CFA+

Wire coding §  Wires are coded by wire color and cross-section

§  Wires are coded by printed numbers

§  Wires are coded by printed function of the wire

Certification

  • The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355

Genset Standard Features

Assembly:

Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.

Fabrication:

– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.

– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.

– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.

– The control panel enclosure is made up of reliable metal sheet.

Paint:

-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.

– Paints passed durability tests conforming to international quality standards.

– Impact (EN ISO 6272)

– Salt Spray Resistance (ASTM B117-73)

– Humidity Resistance (ASTM D2247)

Works-Testing:

– All Gensets are tested prior to dispatch.

– Test is automatically generated and checked according to ISO8528

– Test certificate is issued for each Genset

Equipment:

– Water cooled Radiator with belt driven blower fan and full guarding

– Electric starter with solenoid Relay

– Battery Charging Alternator

– Energized to run solenoid

– Replaceable fuel, oil and air filters

– Heavy duty leads acid battery with matching capacity (Amps & CCA)

– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.

– Integral Fuel Tank with 340 L capacity.

Documentation:

– User Manual for Operation, Installation and Maintenance guidance

– Wring Diagram.

– Test Report

– Maintenance Schedule

– Catalogues for Engine, Alternator & AVR

Genset Optional Features

Manual & Automatic Transfer Switches,

Synchronizing & Totalizing Panels

Fuel water separator

Water jacket heater

Oil heater

Fuel heater

Battery heater

Anti-condensation Heater

Air Shut-off Valve

Oil Sampler

Pre-lube Oil Pump

 

 

 

 The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.

NOTES

  1. The applicable voltage is 220V for 60Hz applications. For other voltages, please consult factory.
  2. This generating set is of fixed speed of 1800 rpm.
  3. CT3150 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
  4. CT3500S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data
Make & Model CUMMINS QSK78-G8
Cylinders & Arrangement 18, 60° Vee
Bore & Stroke (mm) 170×190 mm
Induction system Turbo Charged & Aftercooled
Combustion Direct injection
Cycle 4 stroke
Compression ratio 15.5: 1
Cooling System Water cooled
Displacement 77.6 liters
Lube oil capacity 465.6 liters Max
Coolant capacity 223.4 liters
Standard governor Electronic
Engine Speed 1800 rpm
Consumption @ 100% Load (L/H) 634
Consumption @ 75% Load (L/H) 500
Consumption @ 50% Load (L/H) 352
Consumption @ 25% Load (L/H) 201
Radiator Cooling Air Flow (m3/s) 45.0
Emissions regulations For non-regulated territories
Exhaust temperature ᵒC (max) 435
Max exhaust gas flow (m3/min) 517.1
Max. allowed back pressure (kPa) 7.0

The above performance data are valid as per the following specs:

  • Diesel Fuel is according to BS2869 Class A2 or equivalent.
  • Lubricating oil is according to Grade SAE 15W-40 API CI4.
  • The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data  
Make & Model Leroy Somer LSA52.3M9 (8S)
Frequency / No. of poles 60Hz / 4P
Ingress protection IP23
Insulation class H
Terminals (Optional) 6
Excitation system AREP + PMI
Winding pitch 2/3
AVR model D 510C
Overspeed 2250 R.P.M.
Voltage regulation ± 0.5 %
Coolant air flow 2.8 m3/s

 Certification

  • The complete generating set is type-tested according to ISO 8528-8 standard.

 

Control Panel Specifications

GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939.  It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.

Circuit Breaker Schneider or ABB, 3 Pole ACB (4 Pole available as Optional)

Construction

Sheet Fabrication CNC shearing & bending
Paint type Heat-treated powder-coated
Paint application Electrostatic corona spraying
Durability tests §  IMPACT [EN ISO 6272]

§  Salt spray resistance [ASTM B117-73]

§  Humidity Resistance [ASTM D2247]

Compliance §  Panel is compliant with [ISO8528-8]

§  Clearance & Creepage [IEC60355-1]

§  Leakage current & Dielectric strength [IEC60355-1]

§  Protection against electric shock [IEC600 364-4-41]

Degree of protection IP55
Wire crimping §  Crimping force up to 20KN

§  Accuracy of 0.01mm

§  Each crimping is checked by Komax CFA+

Wire coding §  Wires are coded by wire color and cross-section

§  Wires are coded by printed numbers

§  Wires are coded by printed function of the wire

Certification

  • The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355

Genset Standard Features 

Assembly:

Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.

Fabrication:

– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.

– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.

– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.

– The control panel enclosure is made up of reliable metal sheet.

Paint:

-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.

– Paints passed durability tests conforming to international quality standards.

– Impact (EN ISO 6272)

– Salt Spray Resistance (ASTM B117-73)

– Humidity Resistance (ASTM D2247)

Works-Testing:

– All Gensets are tested prior to dispatch.

– Test is automatically generated and checked according to ISO8528

– Test certificate is issued for each Genset

Equipment:

– Water cooled Radiator with belt driven blower fan and full guarding

– Electric starter with solenoid Relay

– Battery Charging Alternator

– Energized to run solenoid

– Replaceable fuel, oil and air filters

– Heavy duty leads acid battery with matching capacity (Amps & CCA)

– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.

Documentation:

– User Manual for Operation, Installation and Maintenance guidance

– Wring Diagram.

– Test Report

– Maintenance Schedule

– Catalogues for Engine, Alternator & AVR

Genset Optional Features

Manual & Automatic Transfer Switches,

Synchronizing & Totalizing Panels

Fuel water separator

Water jacket heater

Oil heater

Fuel heater

Battery heater

Anti-condensation Heater

Air Shut-off Valve

Oil Sampler

Pre-lube Oil Pump

 

 

 

The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.

NOTES

  1. The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
  2. This generating set is of fixed speed of 1800 rpm.
  3. CT350 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
  4. CT380S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data
Make & Model CUMMINS QSL9-G5
Cylinders & Arrangement 6; in-line
Bore & Stroke (mm) 114×145 mm
Induction system Turbo Charged & Aftercooled
Combustion Direct injection
Cycle 4 stroke
Compression ratio 17.8: 1
Cooling System Water cooled
Displacement 8.8 liters
Lube oil capacity 26.5 liters Max
Coolant capacity 11.0 liters
Standard governor Electronic
Engine Speed 1800 rpm
Consumption @ 100% Load (L/H) 75
Consumption @ 75% Load (L/H) 55
Consumption @ 50% Load (L/H) 36
Consumption @ 25% Load (L/H) 20
Radiator Cooling Air Flow (m3/s) 8.0
Emissions regulations For non-regulated territories
Exhaust temperature ᵒC (max) 500
Max exhaust gas flow (m3/min) 55.8
Max. allowed back pressure (kPa) 10.2

The above performance data are valid as per the following specs:

  • Diesel Fuel is according to BS2869 Class A2 or equivalent.
  • Lubricating oil is according to Grade SAE 15W-40 API CI4.
  • The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data  
Make & Model Leroy Somer TAL046H
Frequency / No. of poles 60Hz / 4P
Ingress protection IP23
Insulation class H
Terminals (Optional) 6 (12)
Excitation system SHUNT
Winding pitch 2/3
AVR model R150
Overspeed 2250 R.P.M.
Voltage regulation ± 1 %
Coolant air flow 0.58 m3/s

Certification

  • The complete generating set is type-tested according to ISO 8528-8 standard.

 

Control Panel Specifications

GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939.  It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.

Circuit Breaker Schneider or ABB, 3 Pole MCCB (4 Pole available as Optional)

Construction

Sheet Fabrication CNC shearing & bending
Paint type Heat-treated powder-coated
Paint application Electrostatic corona spraying
Durability tests §  IMPACT [EN ISO 6272]

§  Salt spray resistance [ASTM B117-73]

§  Humidity Resistance [ASTM D2247]

Compliance §  Panel is compliant with [ISO8528-8]

§  Clearance & Creepage [IEC60355-1]

§  Leakage current & Dielectric strength [IEC60355-1]

§  Protection against electric shock [IEC600 364-4-41]

Degree of protection IP55
Wire crimping §  Crimping force up to 20KN

§  Accuracy of 0.01mm

§  Each crimping is checked by Komax CFA+

Wire coding §  Wires are coded by wire color and cross-section

§  Wires are coded by printed numbers

§  Wires are coded by printed function of the wire

 

Certification

  • The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355

Genset Standard Features

Assembly:

Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.

Fabrication:

– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.

– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.

– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.

– The control panel enclosure is made up of reliable metal sheet.

Paint:

-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.

– Paints passed durability tests conforming to international quality standards.

– Impact (EN ISO 6272)

– Salt Spray Resistance (ASTM B117-73)

– Humidity Resistance (ASTM D2247)

Works-Testing:

– All Gensets are tested prior to dispatch.

– Test is automatically generated and checked according to ISO8528

– Test certificate is issued for each Genset

Equipment:

– Water cooled Radiator with belt driven blower fan and full guarding

– Electric starter with solenoid Relay

– Battery Charging Alternator

– Energized to run solenoid

– Replaceable fuel, oil and air filters

– Heavy duty leads acid battery with matching capacity (Amps & CCA)

– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.

– Integral Fuel Tank with 340 L capacity.

Documentation:

– User Manual for Operation, Installation and Maintenance guidance

– Wring Diagram.

– Test Report

– Maintenance Schedule

– Catalogues for Engine, Alternator & AVR

Genset Optional Features

Manual & Automatic Transfer Switches,

Synchronizing & Totalizing Panels

Fuel water separator

Water jacket heater

Oil heater

Fuel heater

Battery heater

Anti-condensation Heater

Air Shut-off Valve

Oil Sampler

Pre-lube Oil Pump

 

 

 

 

The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.

 NOTES

  1. The applicable voltage is 220V for 60Hz applications. For other voltages, please consult factory.
  2. This generating set is of fixed speed of 1800 rpm.
  3. CT3650 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
  4. CT4000S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data
Make & Model CUMMINS QSK95-G9
Cylinders & Arrangement 16, 60° Vee
Bore & Stroke (mm) 190×210 mm
Induction system Turbo Charged & Aftercooled
Combustion Direct injection
Cycle 4 stroke
Compression ratio 15.5: 1
Cooling System Water cooled
Displacement 95.0 liters
Lube oil capacity 647 liters Max
Coolant capacity 380 liters
Standard governor Electronic
Engine Speed 1800 rpm
Consumption @ 100% Load (L/H) 787
Consumption @ 75% Load (L/H) 603
Consumption @ 50% Load (L/H) 437
Consumption @ 25% Load (L/H) 244
Radiator Cooling Air Flow (m3/s) TBA
Emissions regulations For non-regulated territories
Exhaust temperature ᵒC (max) 444
Max exhaust gas flow (m3/min) 661.9
Max. allowed back pressure (kPa) 7.0

The above performance data are valid as per the following specs:

  • Diesel Fuel is according to BS2869 Class A2 or equivalent.
  • Lubricating oil is according to Grade SAE 15W-40 API CI4.
  • The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data  
Make & Model Leroy Somer LSA54.2M10 (8S)
Frequency / No. of poles 60Hz / 4P
Ingress protection IP23
Insulation class H
Terminals (Optional) 6
Excitation system AREP + PMI
Winding pitch 2/3
AVR model D 510C
Overspeed 2160 R.P.M.
Voltage regulation ± 0.5 %
Coolant air flow 3.0 m3/s

 Certification

  • The complete generating set is type-tested according to ISO 8528-8 standard.

 

Control Panel Specifications

GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939.  It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.

Circuit Breaker Schneider or ABB, 3 Pole ACB (4 Pole available as Optional)

Construction

Sheet Fabrication CNC shearing & bending
Paint type Heat-treated powder-coated
Paint application Electrostatic corona spraying
Durability tests §  IMPACT [EN ISO 6272]

§  Salt spray resistance [ASTM B117-73]

§  Humidity Resistance [ASTM D2247]

Compliance §  Panel is compliant with [ISO8528-8]

§  Clearance & Creepage [IEC60355-1]

§  Leakage current & Dielectric strength [IEC60355-1]

§  Protection against electric shock [IEC600 364-4-41]

Degree of protection IP55
Wire crimping §  Crimping force up to 20KN

§  Accuracy of 0.01mm

§  Each crimping is checked by Komax CFA+

Wire coding §  Wires are coded by wire color and cross-section

§  Wires are coded by printed numbers

§  Wires are coded by printed function of the wire

Certification

  • The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355

Genset Standard Features

Assembly:

Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard. 

Fabrication:

– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.

– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.

– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.

– The control panel enclosure is made up of reliable metal sheet.

Paint:

-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.

– Paints passed durability tests conforming to international quality standards.

– Impact (EN ISO 6272)

– Salt Spray Resistance (ASTM B117-73)

– Humidity Resistance (ASTM D2247)

Works-Testing:

– All Gensets are tested prior to dispatch.

– Test is automatically generated and checked according to ISO8528

– Test certificate is issued for each Genset

Equipment:

– Water cooled Radiator with belt driven blower fan and full guarding

– Electric starter with solenoid Relay

– Battery Charging Alternator

– Energized to run solenoid

– Replaceable fuel, oil and air filters

– Heavy duty leads acid battery with matching capacity (Amps & CCA)

– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.

Documentation:

– User Manual for Operation, Installation and Maintenance guidance

– Wring Diagram.

– Test Report

– Maintenance Schedule

– Catalogues for Engine, Alternator & AVR

Genset Optional Features

Manual & Automatic Transfer Switches,

Synchronizing & Totalizing Panels

Fuel water separator

Water jacket heater

Oil heater

Fuel heater

Battery heater

Anti-condensation Heater

Air Shut-off Valve

Oil Sampler

Pre-lube Oil Pump

 

 

 

 

The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.

NOTES

  1. The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
  2. This generating set is of fixed speed of 1800 rpm.
  3. CT400 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
  4. CT440S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
  5. This rating level at voltage 220/380 is achieved when upsizing alternator to TAL047A
Engine Technical Data
Make & Model CUMMINS NTA855-G4
Cylinders & Arrangement 6; in-line
Bore & Stroke (mm) 140×152 mm
Induction system Turbo Charged & Aftercooled
Combustion Direct injection
Cycle 4 stroke
Compression ratio 14.0: 1
Cooling System Water cooled
Displacement 14.0 liters
Lube oil capacity 38.6 liters Max
Coolant capacity 20.8 liters
Standard governor Electronic
Engine Speed 1800 rpm
Consumption @ 100% Load (L/H) 87
Consumption @ 75% Load (L/H) 66
Consumption @ 50% Load (L/H) 47
Consumption @ 25% Load (L/H) 27
Radiator Cooling Air Flow (m3/s) 7.2
Emissions regulations For non-regulated territories
Exhaust temperature ᵒC (max) 521
Max exhaust gas flow (m3/min) 78.9
Max. allowed back pressure (kPa) 10.2

The above performance data are valid as per the following specs:

  • Diesel Fuel is according to BS2869 Class A2 or equivalent.
  • Lubricating oil is according to Grade SAE 15W-40 API CI4.
  • The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data    
Make & Model Leroy Somer TAL046H Leroy Somer TAL047A
Frequency / No. of poles 60Hz / 4P 60Hz / 4P
Ingress protection IP23 IP23
Insulation class H H
Terminals (Optional) 6 (12) 6 (12)
Excitation system SHUNT SHUNT
Winding pitch 2/3 2/3
AVR model R150 R150
Overspeed 2250 R.P.M. 2250 R.P.M.
Voltage regulation ± 1 % ± 0.9 %
Coolant air flow 0.58 m3/s 0.9 m3/s

 Certification

  • The complete generating set is type-tested according to ISO 8528-8 standard.

 

Control Panel Specifications

GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939.  It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.

Circuit Breaker Schneider or ABB, 3 Pole MCCB (4 Pole available as Optional)

Construction

Sheet Fabrication CNC shearing & bending
Paint type Heat-treated powder-coated
Paint application Electrostatic corona spraying
Durability tests §  IMPACT [EN ISO 6272]

§  Salt spray resistance [ASTM B117-73]

§  Humidity Resistance [ASTM D2247]

Compliance §  Panel is compliant with [ISO8528-8]

§  Clearance & Creepage [IEC60355-1]

§  Leakage current & Dielectric strength [IEC60355-1]

§  Protection against electric shock [IEC600 364-4-41]

Degree of protection IP55
Wire crimping §  Crimping force up to 20KN

§  Accuracy of 0.01mm

§  Each crimping is checked by Komax CFA+

Wire coding §  Wires are coded by wire color and cross-section

§  Wires are coded by printed numbers

§  Wires are coded by printed function of the wire

Certification

  • The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355

Genset Standard Features

Assembly:

Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.

Fabrication:

– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.

– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.

– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.

– The control panel enclosure is made up of reliable metal sheet.

Paint:

-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.

– Paints passed durability tests conforming to international quality standards.

– Impact (EN ISO 6272)

– Salt Spray Resistance (ASTM B117-73)

– Humidity Resistance (ASTM D2247)

Works-Testing:

– All Gensets are tested prior to dispatch.

– Test is automatically generated and checked according to ISO8528

– Test certificate is issued for each Genset

Equipment:

– Water cooled Radiator with belt driven blower fan and full guarding

– Electric starter with solenoid Relay

– Battery Charging Alternator

– Energized to run solenoid

– Replaceable fuel, oil and air filters

– Heavy duty leads acid battery with matching capacity (Amps & CCA)

– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.

– Integral Fuel Tank with 355 L capacity.

Documentation:

– User Manual for Operation, Installation and Maintenance guidance

– Wring Diagram.

– Test Report

– Maintenance Schedule

– Catalogues for Engine, Alternator & AVR

Genset Optional Features

Manual & Automatic Transfer Switches,

Synchronizing & Totalizing Panels

Fuel water separator

Water jacket heater

Oil heater

Fuel heater

Battery heater

Anti-condensation Heater

Air Shut-off Valve

Oil Sampler

Pre-lube Oil Pump

 

 

The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.

NOTES

  1. The applicable voltage range is 380V to 480V for 60Hz applications. For other voltages, please consult factory.

  2. This generating set is of fixed speed of 1800 rpm.

  3. CT425 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.

  4. CT460S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.

Engine Technical Data

Make & Model

CUMMINS QSG12-G3

Cylinders & Arrangement

6; Vertical in-line

Bore & Stroke (mm)

132 x 144

Induction system

Turbo Charged & Aftercooled

Combustion

Direct injection

Cycle

4 stroke

Compression ratio

17.0: 1

Cooling System

Water cooled

Displacement

11.8 liters

Lube oil capacity

34 liters Max

Coolant capacity

48 liters

Standard governor

Electronic; Cummins CM2880

Engine Speed

1800 rpm

Consumption @ 100% Load (L/H)

85

Consumption @ 75% Load (L/H)

62

Consumption @ 50% Load (L/H)

8.4

Consumption @ 25% Load (L/H)

43

Radiator Cooling Air Flow (m3/s)

24

Emissions regulations

Fuel optimized

Exhaust temperature ᵒC (max)

530

Max exhaust gas flow (m3/min)

65

Max. allowed back pressure (kPa)

10.2

The above performance data are valid as per the following specs:
• Diesel Fuel is according to BS2869 Class A2 or equivalent.
• Lubricating oil is according to Grade SAE 15W-40 API CI4.
• The coolant should be 50% antifreeze and 50% fresh water.
Anti-freeze should be compliant with ASTM D6210.

Alternator Technical Data

Make & Model

Leroy Somer TAL0473A – TAL46H

Frequency / No. of poles

60Hz / 4P

Ingress protection

IP23

Insulation class

H

Terminals (Optional)

6 (12)

Excitation system

SHUNT (AREP +or PMG)

Winding pitch

2/3

AVR model

R150

Overspeed

2250 R.P.M.

Voltage regulation

± 1 %

Coolant air flow

1.1 m3/s

Certification

  • The complete generating set is type-tested according to ISO 8528-8 standard.

Control Panel Specifications

GMP260MKIII (DSE6110 MKIII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939. It is fully configurable by PC software, yet most settings can be programmed by front fascia buttons. If Mains voltage is to be monitored, DSE6120MKIII can be offered.
Circuit Breaker Schneider or ABB, 3 Pole (4 Pole
available as Optional)

Construction

Sheet Fabrication

CNC shearing & bending

Paint type

Heat-treated powder-coated

Paint application

Electrostatic corona spraying

Durability tests

  • IMPACT [EN ISO 6272]
  • Salt spray resistance [ASTM B117-73]
  • Humidity Resistance [ASTM D2247]

Compliance

  • Panel is compliant with [ISO8528-8]

  • Clearance & Creepage [IEC60355-1]

  • Leakage current & Dielectric strength [IEC60355-1]

  • Protection against electric shock [IEC600 364-4-41]

Degree of protection

IP55

Wire crimping

  • Crimping force up to 20KN

  • Accuracy of 0.01mm

  • Each crimping is checked by Komax CFA+

Wire coding

  • Wires are coded by wire color and cross-section

  • Wires are coded by printed numbers

  • Wires are coded by printed function of the wire

Genset Standard Features

Assembly:

Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.

Fabrication:

– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.

– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.

– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.

– The control panel enclosure is made up of reliable metal sheet.

Paint:

-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.

– Paints passed durability tests conforming to international quality standards.

– Impact (EN ISO 6272)

– Salt Spray Resistance (ASTM B117-73)

– Humidity Resistance (ASTM D2247)

Works-Testing:

– All Gensets are tested prior to dispatch.

– Test is automatically generated and checked according to ISO8528

– Test certificate is issued for each Genset

Equipment:

– Water cooled Radiator with belt driven blower fan and full guarding

– Electric starter with solenoid Relay

– Battery Charging Alternator

– Energized to run solenoid

– Replaceable fuel, oil and air filters

– Heavy duty leads acid battery with matching capacity (Amps & CCA)

– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.

– Integral Fuel Tank with 150 L capacity.

Documentation:

– User Manual for Operation, Installation and Maintenance guidance

– Wring Diagram.

– Test Report

– Maintenance Schedule

– Catalogues for Engine, Alternator & AVR

Genset Optional Features

Manual & Automatic Transfer Switches,

Synchronizing & Totalizing Panels

Fuel water separator

Water jacket heater

Oil heater

Fuel heater

Battery heater

Anti-condensation Heater

Air Shut-off Valve

Oil Sampler

Pre-lube Oil Pump

 

 

 

The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.

NOTES

  1. The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
  2. This generating set is of fixed speed of 1800 rpm.
  3. CT450 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
  4. CT490S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data
Make & Model CUMMINS QSX15-G8
Cylinders & Arrangement 6; in-line
Bore & Stroke (mm) 137×169 mm
Induction system Turbo Charged & Aftercooled
Combustion Direct injection
Cycle 4 stroke
Compression ratio 17.0: 1
Cooling System Water cooled
Displacement 15 liters
Lube oil capacity 91 liters Max
Coolant capacity 24 liters
Standard governor Electronic
Engine Speed 1800 rpm
Consumption @ 100% Load (L/H) 97.6
Consumption @ 75% Load (L/H) 75.2
Consumption @ 50% Load (L/H) 53.4
Consumption @ 25% Load (L/H) 31.8
Radiator Cooling Air Flow (m3/s) 11.8
Emissions regulations For non-regulated territories
Exhaust temperature ᵒC (max) 435
Max exhaust gas flow (m3/min) 82.2
Max. allowed back pressure (kPa) 10.0

The above performance data are valid as per the following specs:

  • Diesel Fuel is according to BS2869 Class A2 or equivalent.
  • Lubricating oil is according to Grade SAE 15W-40 API CI4.
  • The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data  
Make & Model Leroy Somer TAL047C
Frequency / No. of poles 60Hz / 4P
Ingress protection IP23
Insulation class H
Terminals (Optional) 6 (12)
Excitation system SHUNT
Winding pitch 2/3
AVR model R150
Overspeed 2250 R.P.M.
Voltage regulation ± 1 %
Coolant air flow 1.1 m3/s

 Certification

  • The complete generating set is type-tested according to ISO 8528-8 standard.

 

Control Panel Specifications

GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939.  It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.

Circuit Breaker Schneider or ABB, 3 Pole MCCB (4 Pole available as Optional)

Construction

Sheet Fabrication CNC shearing & bending
Paint type Heat-treated powder-coated
Paint application Electrostatic corona spraying
Durability tests §  IMPACT [EN ISO 6272]

§  Salt spray resistance [ASTM B117-73]

§  Humidity Resistance [ASTM D2247]

Compliance §  Panel is compliant with [ISO8528-8]

§  Clearance & Creepage [IEC60355-1]

§  Leakage current & Dielectric strength [IEC60355-1]

§  Protection against electric shock [IEC600 364-4-41]

Degree of protection IP55
Wire crimping §  Crimping force up to 20KN

§  Accuracy of 0.01mm

§  Each crimping is checked by Komax CFA+

Wire coding §  Wires are coded by wire color and cross-section

§  Wires are coded by printed numbers

§  Wires are coded by printed function of the wire

Certification

  • The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355

Genset Standard Features

Assembly:

Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.

Fabrication:

– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.

– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.

– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.

– The control panel enclosure is made up of reliable metal sheet.

Paint:

-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.

– Paints passed durability tests conforming to international quality standards.

– Impact (EN ISO 6272)

– Salt Spray Resistance (ASTM B117-73)

– Humidity Resistance (ASTM D2247)

Works-Testing:

– All Gensets are tested prior to dispatch.

– Test is automatically generated and checked according to ISO8528

– Test certificate is issued for each Genset

Equipment:

– Water cooled Radiator with belt driven blower fan and full guarding

– Electric starter with solenoid Relay

– Battery Charging Alternator

– Energized to run solenoid

– Replaceable fuel, oil and air filters

– Heavy duty leads acid battery with matching capacity (Amps & CCA)

– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.

– Integral Fuel Tank with 355 L capacity.

Documentation:

– User Manual for Operation, Installation and Maintenance guidance

– Wring Diagram.

– Test Report

– Maintenance Schedule

– Catalogues for Engine, Alternator & AVR

Genset Optional Features

Manual & Automatic Transfer Switches,

Synchronizing & Totalizing Panels

Fuel water separator

Water jacket heater

Oil heater

Fuel heater

Battery heater

Anti-condensation Heater

Air Shut-off Valve

Oil Sampler

Pre-lube Oil Pump

 

 

 

 

The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.

NOTES

  1. The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
  2. This generating set is of fixed speed of 1800 rpm.
  3. CT450 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
  4. CT500S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
  5. This rating level at voltage 220/380 is achieved when upsizing alternator to TAL047E
Engine Technical Data
Make & Model CUMMINS QSZ13-G7
Cylinders & Arrangement 6; in-line
Bore & Stroke (mm) 130×163 mm
Induction system Turbo Charged & Aftercooled
Combustion Direct injection
Cycle 4 stroke
Compression ratio 17.0: 1
Cooling System Water cooled
Displacement 13 liters
Lube oil capacity 75.3 liters Max
Coolant capacity 23.1 liters
Standard governor Electronic
Engine Speed 1800 rpm
Consumption @ 100% Load (L/H) 101.3
Consumption @ 75% Load (L/H) 82.4
Consumption @ 50% Load (L/H) 59.4
Consumption @ 25% Load (L/H) 35.9
Radiator Cooling Air Flow (m3/s) 10.3
Emissions regulations For non-regulated territories
Exhaust temperature ᵒC (max) 454
Max exhaust gas flow (m3/min) 81.7
Max. allowed back pressure (kPa) 13.0

The above performance data are valid as per the following specs:

  • Diesel Fuel is according to BS2869 Class A2 or equivalent.
  • Lubricating oil is according to Grade SAE 15W-40 API CI4.
  • The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data  
Make & Model Leroy Somer TAL047A
Frequency / No. of poles 60Hz / 4P
Ingress protection IP23
Insulation class H
Terminals (Optional) 6 (12)
Excitation system SHUNT
Winding pitch 2/3
AVR model R150
Overspeed 2250 R.P.M.
Voltage regulation ± 1 %
Coolant air flow 0.9 m3/s

Certification

  • The complete generating set is type-tested according to ISO 8528-8 standard.

 

Control Panel Specifications

GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939.  It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.

Circuit Breaker Schneider or ABB, 3 Pole MCCB (4 Pole available as Optional)

Construction

Sheet Fabrication CNC shearing & bending
Paint type Heat-treated powder-coated
Paint application Electrostatic corona spraying
Durability tests §  IMPACT [EN ISO 6272]

§  Salt spray resistance [ASTM B117-73]

§  Humidity Resistance [ASTM D2247]

Compliance §  Panel is compliant with [ISO8528-8]

§  Clearance & Creepage [IEC60355-1]

§  Leakage current & Dielectric strength [IEC60355-1]

§  Protection against electric shock [IEC600 364-4-41]

Degree of protection IP55
Wire crimping §  Crimping force up to 20KN

§  Accuracy of 0.01mm

§  Each crimping is checked by Komax CFA+

Wire coding §  Wires are coded by wire color and cross-section

§  Wires are coded by printed numbers

§  Wires are coded by printed function of the wire

 

Certification

  • The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355

Genset Standard Features

Assembly:

Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.

Fabrication:

– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.

– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.

– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.

– The control panel enclosure is made up of reliable metal sheet.

Paint:

-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.

– Paints passed durability tests conforming to international quality standards.

– Impact (EN ISO 6272)

– Salt Spray Resistance (ASTM B117-73)

– Humidity Resistance (ASTM D2247)

Works-Testing:

– All Gensets are tested prior to dispatch.

– Test is automatically generated and checked according to ISO8528

– Test certificate is issued for each Genset

Equipment:

– Water cooled Radiator with belt driven blower fan and full guarding

– Electric starter with solenoid Relay

– Battery Charging Alternator

– Energized to run solenoid

– Replaceable fuel, oil and air filters

– Heavy duty leads acid battery with matching capacity (Amps & CCA)

– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.

– Integral Fuel Tank with 355 L capacity.

Documentation:

– User Manual for Operation, Installation and Maintenance guidance

– Wring Diagram.

– Test Report

– Maintenance Schedule

– Catalogues for Engine, Alternator & AVR

Genset Optional Features

Manual & Automatic Transfer Switches,

Synchronizing & Totalizing Panels

Fuel water separator

Water jacket heater

Oil heater

Fuel heater

Battery heater

Anti-condensation Heater

Air Shut-off Valve

Oil Sampler

Pre-lube Oil Pump

 

 

 

The above ratings represent the generating set capability guaranteed within ±3%
at the reference conditions equivalent to those specified in ISO 8528/1 standard.

NOTES:

1. The applicable voltage range is 380V to 480V for 60Hz applications. For other voltages, please consult factory.
2. This generating set is of fixed speed of 1800 rpm.
3. CT485 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
4. CT530S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.

Engine Technical Data
Make & Model CUMMINS QSG12-G4
Cylinders & Arrangement 6; Vertical in-line
Bore & Stroke (mm) 132 x 144mm
Induction system Turbo Charged & Aftercooled
Combustion Direct injection
Cycle 4 stroke
Compression ratio 17.0: 1
Cooling System Water cooled
Displacement 11.8 liters
Lube oil capacity 34 liters Max
Coolant capacity 48 liters
Standard governor Electronic; Cummins CM2880
Engine Speed 1800 rpm
Consumption @ 100% Load (L/H) 96
Consumption @ 75% Load (L/H) 69
Consumption @ 50% Load (L/H) 47
Consumption @ 25% Load (L/H) 26
Radiator Cooling Air Flow (m3/s) 8.4
Emissions regulations Fuel optimized
Exhaust temperature ᵒC (max) 550
Max exhaust gas flow (m3/min) 67
Max. allowed back pressure (kPa) 10.2

The above performance data are valid as per the following specs:

  • Diesel Fuel is according to BS2869 Class A2 or equivalent.
  • Lubricating oil is according to Grade SAE 15W-40 API CI4.
  • The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data  
Make & Model Leroy Somer TAL0473C – [TAL473A]
Frequency / No. of poles 60Hz / 4P
Ingress protection IP23
Insulation class H
Terminals  6(12)
Excitation system SHUNT (AREP +or PMG)
Winding pitch 2/3
AVR model R150
Overspeed 2250 R.P.M.
Voltage regulation ± 1 %
Coolant air flow 1.1 m3/s

Control Panel Specifications

GMP260MKIII (DSE6110 MKIII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939. It is fully configurable by PC software, yet most settings can be programmed by front fascia buttons. If Mains voltage is to be monitored, DSE6120MKIIIcan be offered.
Circuit Breaker Schneider or ABB, 3 Pole (4 Pole
available as Optional).

Construction

Sheet Fabrication

CNC shearing & bending

Paint type

Heat-treated powder-coated

Paint application

Electrostatic corona spraying

Durability tests

  • IMPACT [EN ISO 6272]
  • Salt spray resistance [ASTM B117-73]
  • Humidity Resistance [ASTM D2247]

Compliance

  • Panel is compliant with [ISO8528-8]

  • Clearance & Creepage [IEC60355-1]

  • Leakage current & Dielectric strength [IEC60355-1]

  • Protection against electric shock [IEC600 364-4-41]

Degree of protection

IP55

Wire crimping

  • Crimping force up to 20KN

  • Accuracy of 0.01mm

  • Each crimping is checked by Komax CFA+

Wire coding

  • Wires are coded by wire color and cross-section

  • Wires are coded by printed numbers

  • Wires are coded by printed function of the wire

Genset Standard Features

Assembly:

Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.

Fabrication:

– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.

– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.

– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.

– The control panel enclosure is made up of reliable metal sheet.

Paint:

-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.

– Paints passed durability tests conforming to international quality standards.

– Impact (EN ISO 6272)

– Salt Spray Resistance (ASTM B117-73)

– Humidity Resistance (ASTM D2247)

Works-Testing:

– All Gensets are tested prior to dispatch.

– Test is automatically generated and checked according to ISO8528

– Test certificate is issued for each Genset

Equipment:

– Water cooled Radiator with belt driven blower fan and full guarding

– Electric starter with solenoid Relay

– Battery Charging Alternator

– Energized to run solenoid

– Replaceable fuel, oil and air filters

– Heavy duty leads acid battery with matching capacity (Amps & CCA)

– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.

– Integral Fuel Tank with 150 L capacity.

Documentation:

– User Manual for Operation, Installation and Maintenance guidance

– Wring Diagram.

– Test Report

– Maintenance Schedule

– Catalogues for Engine, Alternator & AVR

Genset Optional Features

Manual & Automatic Transfer Switches,

Synchronizing & Totalizing Panels

Fuel water separator

Water jacket heater

Oil heater

Fuel heater

Battery heater

Anti-condensation Heater

Air Shut-off Valve

Oil Sampler

Pre-lube Oil Pump

 

 

 

 

The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.

 NOTES

  1. The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
  2. This generating set is of fixed speed of 1800 rpm.
  3. CT510 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
  4. CT570S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
Engine Technical Data
Make & Model CUMMINS QSZ13-G5
Cylinders & Arrangement 6; in-line
Bore & Stroke (mm) 130×163 mm
Induction system Turbo Charged & Aftercooled
Combustion Direct injection
Cycle 4 stroke
Compression ratio 17.0: 1
Cooling System Water cooled
Displacement 13 liters
Lube oil capacity 75.3 liters Max
Coolant capacity 23.1 liters
Standard governor Electronic
Engine Speed 1800 rpm
Consumption @ 100% Load (L/H) 102.1
Consumption @ 75% Load (L/H) 76.6
Consumption @ 50% Load (L/H) 51.8
Consumption @ 25% Load (L/H) 34.4
Radiator Cooling Air Flow (m3/s) 10.3
Emissions regulations For non-regulated territories
Exhaust temperature ᵒC (max) 445
Max exhaust gas flow (m3/min) 83.0
Max. allowed back pressure (kPa) 13.0

The above performance data are valid as per the following specs:

  • Diesel Fuel is according to BS2869 Class A2 or equivalent.
  • Lubricating oil is according to Grade SAE 15W-40 API CI4.
  • The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data  
Make & Model Leroy Somer TAL047C
Frequency / No. of poles 60Hz / 4P
Ingress protection IP23
Insulation class H
Terminals (Optional) 6 (12)
Excitation system SHUNT
Winding pitch 2/3
AVR model R150
Overspeed 2250 R.P.M.
Voltage regulation ± 1 %
Coolant air flow 1.1 m3/s

Certification

  • The complete generating set is type-tested according to ISO 8528-8 standard.

 

Control Panel Specifications

GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939.  It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.

Circuit Breaker Schneider or ABB, 3 Pole MCCB (4 Pole available as Optional)

Construction

Sheet Fabrication CNC shearing & bending
Paint type Heat-treated powder-coated
Paint application Electrostatic corona spraying
Durability tests §  IMPACT [EN ISO 6272]

§  Salt spray resistance [ASTM B117-73]

§  Humidity Resistance [ASTM D2247]

Compliance §  Panel is compliant with [ISO8528-8]

§  Clearance & Creepage [IEC60355-1]

§  Leakage current & Dielectric strength [IEC60355-1]

§  Protection against electric shock [IEC600 364-4-41]

Degree of protection IP55
Wire crimping §  Crimping force up to 20KN

§  Accuracy of 0.01mm

§  Each crimping is checked by Komax CFA+

Wire coding §  Wires are coded by wire color and cross-section

§  Wires are coded by printed numbers

§  Wires are coded by printed function of the wire

Certification

  • The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355

Genset Standard Features

Assembly:

Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.

Fabrication:

– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.

– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.

– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.

– The control panel enclosure is made up of reliable metal sheet.

Paint:

-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.

– Paints passed durability tests conforming to international quality standards.

– Impact (EN ISO 6272)

– Salt Spray Resistance (ASTM B117-73)

– Humidity Resistance (ASTM D2247)

Works-Testing:

– All Gensets are tested prior to dispatch.

– Test is automatically generated and checked according to ISO8528

– Test certificate is issued for each Genset

Equipment:

– Water cooled Radiator with belt driven blower fan and full guarding

– Electric starter with solenoid Relay

– Battery Charging Alternator

– Energized to run solenoid

– Replaceable fuel, oil and air filters

– Heavy duty leads acid battery with matching capacity (Amps & CCA)

– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.

– Integral Fuel Tank with 355 L capacity.

Documentation:

– User Manual for Operation, Installation and Maintenance guidance

– Wring Diagram.

– Test Report

– Maintenance Schedule

– Catalogues for Engine, Alternator & AVR

Genset Optional Features

Manual & Automatic Transfer Switches,

Synchronizing & Totalizing Panels

Fuel water separator

Water jacket heater

Oil heater

Fuel heater

Battery heater

Anti-condensation Heater

Air Shut-off Valve

Oil Sampler

Pre-lube Oil Pump

 

 

 

 

 

The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard. 

NOTES

  1. The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
  2. This generating set is of fixed speed of 1800 rpm.
  3. CT560 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
  4. CT620S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
  5. This rating level at voltage 220/380 is achieved when upsizing alternator to TAL047E
Engine Technical Data
Make & Model CUMMINS QSX15-G9
Cylinders & Arrangement 6; in-line
Bore & Stroke (mm) 137×169 mm
Induction system Turbo Charged & Aftercooled
Combustion Direct injection
Cycle 4 stroke
Compression ratio 17.0: 1
Cooling System Water cooled
Displacement 15 liters
Lube oil capacity 91 liters Max
Coolant capacity 24 liters
Standard governor Electronic
Engine Speed 1800 rpm
Consumption @ 100% Load (L/H) 117.8
Consumption @ 75% Load (L/H) 90.5
Consumption @ 50% Load (L/H) 65.3
Consumption @ 25% Load (L/H) 37.4
Radiator Cooling Air Flow (m3/s) 11.8
Emissions regulations For non-regulated territories
Exhaust temperature ᵒC (max) 468
Max exhaust gas flow (m3/min) 90.6
Max. allowed back pressure (kPa) 10.0

The above performance data are valid as per the following specs:

  • Diesel Fuel is according to BS2869 Class A2 or equivalent.
  • Lubricating oil is according to Grade SAE 15W-40 API CI4.
  • The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data    
Make & Model Leroy Somer TAL047C Leroy Somer TAL047E
Frequency / No. of poles 60Hz / 4P 60Hz / 4P
Ingress protection IP23 IP23
Insulation class H H
Terminals (Optional) 6 (12) 6 (12)
Excitation system SHUNT SHUNT
Winding pitch 2/3 2/3
AVR model R150 R150
Overspeed 2250 R.P.M. 2250 R.P.M.
Voltage regulation ± 1 % ± 1 %
Coolant air flow 1.1 m3/s 1.1 m3/s

 Certification

  • The complete generating set is type-tested according to ISO 8528-8 standard.

 

Control Panel Specifications

GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939.  It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.

Circuit Breaker Schneider or ABB, 3 Pole MCCB (4 Pole available as Optional)

Construction

Sheet Fabrication CNC shearing & bending
Paint type Heat-treated powder-coated
Paint application Electrostatic corona spraying
Durability tests §  IMPACT [EN ISO 6272]

§  Salt spray resistance [ASTM B117-73]

§  Humidity Resistance [ASTM D2247]

Compliance §  Panel is compliant with [ISO8528-8]

§  Clearance & Creepage [IEC60355-1]

§  Leakage current & Dielectric strength [IEC60355-1]

§  Protection against electric shock [IEC600 364-4-41]

Degree of protection IP55
Wire crimping §  Crimping force up to 20KN

§  Accuracy of 0.01mm

§  Each crimping is checked by Komax CFA+

Wire coding §  Wires are coded by wire color and cross-section

§  Wires are coded by printed numbers

§  Wires are coded by printed function of the wire

Certification

  • The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355

Genset Standard Features

Assembly:

Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.

Fabrication:

– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.

– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.

– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.

– The control panel enclosure is made up of reliable metal sheet.

Paint:

-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.

– Paints passed durability tests conforming to international quality standards.

– Impact (EN ISO 6272)

– Salt Spray Resistance (ASTM B117-73)

– Humidity Resistance (ASTM D2247)

Works-Testing:

– All Gensets are tested prior to dispatch.

– Test is automatically generated and checked according to ISO8528

– Test certificate is issued for each Genset

Equipment:

– Water cooled Radiator with belt driven blower fan and full guarding

– Electric starter with solenoid Relay

– Battery Charging Alternator

– Energized to run solenoid

– Replaceable fuel, oil and air filters

– Heavy duty leads acid battery with matching capacity (Amps & CCA)

– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.

– Integral Fuel Tank with 355 L capacity.

Documentation:

– User Manual for Operation, Installation and Maintenance guidance

– Wring Diagram.

– Test Report

– Maintenance Schedule

– Catalogues for Engine, Alternator & AVR

Genset Optional Features

Manual & Automatic Transfer Switches,

Synchronizing & Totalizing Panels

Fuel water separator

Water jacket heater

Oil heater

Fuel heater

Battery heater

Anti-condensation Heater

Air Shut-off Valve

Oil Sampler

Pre-lube Oil Pump

 

 

 

 

The above ratings represent the generating set capability guaranteed within ±3%
at the reference conditions equivalent to those specified in ISO 8528/1 standard.

NOTES:

1. The applicable voltage range is 380V to 480V for 60Hz applications. For other voltages, please consult factory.
2. This generating set is of fixed speed of 1800 rpm.
3. CT575 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
4. CT635S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.

Engine Technical Data
Make & Model CUMMINS KTA19-G4
Cylinders & Arrangement 6; Vertical in-line
Bore & Stroke (mm) 159 x 159 mm
Induction system Turbo Charged & Aftercooled
Combustion Direct injection
Cycle 4 stroke
Compression ratio 13.9: 1
Cooling System Water cooled
Displacement 18.9 liters
Lube oil capacity 50 liters Max
Coolant capacity 93 liters
Standard governor Electronic; Cummins EFC
Engine Speed 1800 rpm
Consumption @ 100% Load (L/H) 122
Consumption @ 75% Load (L/H) 94
Consumption @ 50% Load (L/H) 65
Consumption @ 25% Load (L/H) 36
Radiator Cooling Air Flow (m3/s) 11.9
Emissions regulations Fuel optimized
Exhaust temperature ᵒC (max) 504
Max exhaust gas flow (m3/min) 112
Max. allowed back pressure (kPa) 10.2

The above performance data are valid as per the following specs:

  • Diesel Fuel is according to BS2869 Class A2 or equivalent.
  • Lubricating oil is according to Grade SAE 15W-40 API CI4.
  • The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data  
Make & Model Leroy Somer TAL0473E – [TAL473C]
Frequency / No. of poles 60Hz / 4P
Ingress protection IP23
Insulation class H
Terminals  6(12)
Excitation system SHUNT (AREP +or PMG)
Winding pitch 2/3
AVR model R150
Overspeed 2250 R.P.M.
Voltage regulation ± 1 %
Coolant air flow  1.1 m3/s

Control Panel Specifications

GMP260MKIII (DSE6110 MKIII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939. It is fully configurable by PC software, yet most settings can be programmed by front fascia buttons. If Mains voltage is to be monitored, DSE6120MKIIIcan be offered.
Circuit Breaker Schneider or ABB, 3 Pole (4 Pole
available as Optional).

Construction

Sheet Fabrication

CNC shearing & bending

Paint type

Heat-treated powder-coated

Paint application

Electrostatic corona spraying

Durability tests

  • IMPACT [EN ISO 6272]
  • Salt spray resistance [ASTM B117-73]
  • Humidity Resistance [ASTM D2247]

Compliance

  • Panel is compliant with [ISO8528-8]

  • Clearance & Creepage [IEC60355-1]

  • Leakage current & Dielectric strength [IEC60355-1]

  • Protection against electric shock [IEC600 364-4-41]

Degree of protection

IP55

Wire crimping

  • Crimping force up to 20KN

  • Accuracy of 0.01mm

  • Each crimping is checked by Komax CFA+

Wire coding

  • Wires are coded by wire color and cross-section

  • Wires are coded by printed numbers

  • Wires are coded by printed function of the wire

Genset Standard Features

Assembly:

Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.

Fabrication:

– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.

– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.

– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.

– The control panel enclosure is made up of reliable metal sheet.

Paint:

-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.

– Paints passed durability tests conforming to international quality standards.

– Impact (EN ISO 6272)

– Salt Spray Resistance (ASTM B117-73)

– Humidity Resistance (ASTM D2247)

Works-Testing:

– All Gensets are tested prior to dispatch.

– Test is automatically generated and checked according to ISO8528

– Test certificate is issued for each Genset

Equipment:

– Water cooled Radiator with belt driven blower fan and full guarding

– Electric starter with solenoid Relay

– Battery Charging Alternator

– Energized to run solenoid

– Replaceable fuel, oil and air filters

– Heavy duty leads acid battery with matching capacity (Amps & CCA)

– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.

– Integral Fuel Tank with 150 L capacity.

Documentation:

– User Manual for Operation, Installation and Maintenance guidance

– Wring Diagram.

– Test Report

– Maintenance Schedule

– Catalogues for Engine, Alternator & AVR

Genset Optional Features

Manual & Automatic Transfer Switches,

Synchronizing & Totalizing Panels

Fuel water separator

Water jacket heater

Oil heater

Fuel heater

Battery heater

Anti-condensation Heater

Air Shut-off Valve

Oil Sampler

Pre-lube Oil Pump

 

 

 

 

The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.

NOTES

  1. The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
  2. This generating set is of fixed speed of 1800 rpm.
  3. CT680 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
  4. CT750S is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
  5. This rating level at voltage 220/380 is achieved when upsizing alternator to TAL047F
Engine Technical Data
Make & Model CUMMINS VTA28-G5
Cylinders & Arrangement 12, 40° Vee
Bore & Stroke (mm) 140×152 mm
Induction system Turbo Charged & Aftercooled
Combustion Direct injection
Cycle 4 stroke
Compression ratio 13.1: 1
Cooling System Water cooled
Displacement 28 liters
Lube oil capacity 83 liters Max
Coolant capacity 80 liters
Standard governor Electronic
Engine Speed 1800 rpm
Consumption @ 100% Load (L/H) 154
Consumption @ 75% Load (L/H) 118
Consumption @ 50% Load (L/H) 84
Consumption @ 25% Load (L/H) 50
Radiator Cooling Air Flow (m3/s) 17.2
Emissions regulations For non-regulated territories
Exhaust temperature ᵒC (max) 507
Max exhaust gas flow (m3/min) 122.9
Max. allowed back pressure (kPa) 10.0

The above performance data are valid as per the following specs:

  • Diesel Fuel is according to BS2869 Class A2 or equivalent.
  • Lubricating oil is according to Grade SAE 15W-40 API CI4.
  • The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data    
Make & Model Leroy Somer TAL047E (8S) Leroy Somer TAL047F
Frequency / No. of poles 60Hz / 4P 60Hz / 4P
Ingress protection IP23 IP23
Insulation class H H
Terminals (Optional) 6 (12) 6 (12)
Excitation system SHUNT SHUNT
Winding pitch 2/3 2/3
AVR model R150 R150
Overspeed 2250 R.P.M. 2250 R.P.M.
Voltage regulation ± 1 % ± 1 %
Coolant air flow 1.1 m3/s 1.1 m3/s

 Certification

  • The complete generating set is type-tested according to ISO 8528-8 standard.

 

Control Panel Specifications

GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939.  It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.

Circuit Breaker Schneider or ABB, 3 Pole MCCB (4 Pole available as Optional)

Construction

Sheet Fabrication CNC shearing & bending
Paint type Heat-treated powder-coated
Paint application Electrostatic corona spraying
Durability tests §  IMPACT [EN ISO 6272]

§  Salt spray resistance [ASTM B117-73]

§  Humidity Resistance [ASTM D2247]

Compliance §  Panel is compliant with [ISO8528-8]

§  Clearance & Creepage [IEC60355-1]

§  Leakage current & Dielectric strength [IEC60355-1]

§  Protection against electric shock [IEC600 364-4-41]

Degree of protection IP55
Wire crimping §  Crimping force up to 20KN

§  Accuracy of 0.01mm

§  Each crimping is checked by Komax CFA+

Wire coding §  Wires are coded by wire color and cross-section

§  Wires are coded by printed numbers

§  Wires are coded by printed function of the wire

Certification

  • The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355

Genset Standard Features

Assembly:

Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.

Fabrication:

– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.

– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.

– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.

– The control panel enclosure is made up of reliable metal sheet.

Paint:

-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.

– Paints passed durability tests conforming to international quality standards.

– Impact (EN ISO 6272)

– Salt Spray Resistance (ASTM B117-73)

– Humidity Resistance (ASTM D2247)

Works-Testing:

– All Gensets are tested prior to dispatch.

– Test is automatically generated and checked according to ISO8528

– Test certificate is issued for each Genset

Equipment:

– Water cooled Radiator with belt driven blower fan and full guarding

– Electric starter with solenoid Relay

– Battery Charging Alternator

– Energized to run solenoid

– Replaceable fuel, oil and air filters

– Heavy duty leads acid battery with matching capacity (Amps & CCA)

– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.

– Integral Fuel Tank with 660 L capacity.

Documentation:

– User Manual for Operation, Installation and Maintenance guidance

– Wring Diagram.

– Test Report

– Maintenance Schedule

– Catalogues for Engine, Alternator & AVR

Genset Optional Features

Manual & Automatic Transfer Switches,

Synchronizing & Totalizing Panels

Fuel water separator

Water jacket heater

Oil heater

Fuel heater

Battery heater

Anti-condensation Heater

Air Shut-off Valve

Oil Sampler

Pre-lube Oil Pump

 

 

 

The above ratings represent the generating set capability guaranteed within ±3% at the reference conditions equivalent to those specified in ISO 8528/1 standard.

NOTES

  1. The applicable voltage range is 220V, 380V to 480V for 60Hz applications. For other voltages, please consult factory.
  2. This generating set is of fixed speed of 1800 rpm.
  3. CT920 is the prime power rating of the generating set is where a variable load and unlimited hour usage are applied with an average load factor of 80% of the prime rating over each 24-hour period. Noting that a 10% overload is permitted for 1 hour in every 12-hour operation.
  4. CT1010 is the standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.
  5. This rating level at voltage 220/380 is achieved when upsizing alternator to TAL049E
Engine Technical Data
Make & Model CUMMINS QSK23-G3
Cylinders & Arrangement 6, In-line
Bore & Stroke (mm) 170×170 mm
Induction system Turbo Charged & Aftercooled
Combustion Direct injection
Cycle 4 stroke
Compression ratio 16.0: 1
Cooling System Water cooled
Displacement 23.2 liters
Lube oil capacity 103 liters Max
Coolant capacity 46.5 liters
Standard governor Electronic
Engine Speed 1800 rpm
Consumption @ 100% Load (L/H) 189
Consumption @ 75% Load (L/H) 139
Consumption @ 50% Load (L/H) 97
Consumption @ 25% Load (L/H) 56
Radiator Cooling Air Flow (m3/s) 16.6
Emissions regulations For non-regulated territories
Exhaust temperature ᵒC (max) 467
Max exhaust gas flow (m3/min) 166.4
Max. allowed back pressure (kPa) 10.2

The above performance data are valid as per the following specs:

  • Diesel Fuel is according to BS2869 Class A2 or equivalent.
  • Lubricating oil is according to Grade SAE 15W-40 API CI4.
  • The coolant should be 50% antifreeze and 50% fresh water.
Alternator Technical Data    
Make & Model Leroy Somer TAL049C Leroy Somer TAL049E
Frequency / No. of poles 60Hz / 4P 60Hz / 4P
Ingress protection IP23 IP23
Insulation class H H
Terminals (Optional) 6 (12) 6 (12)
Excitation system SHUNT SHUNT
Winding pitch 2/3 2/3
AVR model R150 R150
Overspeed 2250 R.P.M. 2250 R.P.M.
Voltage regulation ± 1 % ± 1 %
Coolant air flow 1.2 m3/s 1.2 m3/s

 Certification

  • The complete generating set is type-tested according to ISO 8528-8 standard.

 

Control Panel Specifications

GMP260MK (DSE6010 MKII) panel is an automatic start generating set panel of microprocessor-based design which is capable of interfacing with electronic engine through the can-bus J1939.  It is fully configurable by front fascia buttons and PC software as well. If Mains voltage is to be monitored, DSE6020MKII can be offered.

Circuit Breaker Schneider or ABB, 3 Pole MCCB (4 Pole available as Optional)

Construction

Sheet Fabrication CNC shearing & bending
Paint type Heat-treated powder-coated
Paint application Electrostatic corona spraying
Durability tests §  IMPACT [EN ISO 6272]

§  Salt spray resistance [ASTM B117-73]

§  Humidity Resistance [ASTM D2247]

Compliance §  Panel is compliant with [ISO8528-8]

§  Clearance & Creepage [IEC60355-1]

§  Leakage current & Dielectric strength [IEC60355-1]

§  Protection against electric shock [IEC600 364-4-41]

Degree of protection IP55
Wire crimping §  Crimping force up to 20KN

§  Accuracy of 0.01mm

§  Each crimping is checked by Komax CFA+

Wire coding §  Wires are coded by wire color and cross-section

§  Wires are coded by printed numbers

§  Wires are coded by printed function of the wire

Certification

  • The control panel is certified by an ISO17025 accredited laboratory to have IP55 according to IEC60355

Genset Standard Features

Assembly:

Gensets are assembled at Ghaddar Machinery Factory in compliance with ISO 8528 standard.

Fabrication:

– The engine/alternator assembly rests on skid with Anti-vibration mounting pads.

– The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms.

– A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet and outlet hoses.

– The control panel enclosure is made up of reliable metal sheet.

Paint:

-The skid and control panel enclosure are painted with heat-treated and power-coated electrostatic corona spraying.

– Paints passed durability tests conforming to international quality standards.

– Impact (EN ISO 6272)

– Salt Spray Resistance (ASTM B117-73)

– Humidity Resistance (ASTM D2247)

Works-Testing:

– All Gensets are tested prior to dispatch.

– Test is automatically generated and checked according to ISO8528

– Test certificate is issued for each Genset

Equipment:

– Water cooled Radiator with belt driven blower fan and full guarding

– Electric starter with solenoid Relay

– Battery Charging Alternator

– Energized to run solenoid

– Replaceable fuel, oil and air filters

– Heavy duty leads acid battery with matching capacity (Amps & CCA)

– One loose supplied industrial exhaust silencer – 16 DB noise reduction level.

Documentation:

– User Manual for Operation, Installation and Maintenance guidance

– Wring Diagram.

– Test Report

– Maintenance Schedule

– Catalogues for Engine, Alternator & AVR

Genset Optional Features

Manual & Automatic Transfer Switches,

Synchronizing & Totalizing Panels

Fuel water separator

Water jacket heater

Oil heater

Fuel heater

Battery heater

Anti-condensation Heater

Air Shut-off Valve

Oil Sampler

Pre-lube Oil Pump